Description: Carriage Position Fail Any of the following was detected: • An error with the count value of the Carriage Position Control. • There is no Regi Sensor input during Carriage initialization. • An error with the Regi Sensor detection position.
Remedy: Check the following: • The Pre Regi Sensor (Input Check [062-212]) for operation failure. (PL 1.3) • The Carriage Motor (Output Check [062-005/006] (Scan/Return)) for operation failure. (PL 1.4) • The Drive Belt and Drive Wire for slack and wear. • The Carriage operation for mechanical loading. If no problems are found, replace the ESS/MCU PWB. (PL 18.1)
Code: 062-371, 062-380
Description: Lamp Illumination Fail/ AGC Fail [Lamp Illumination Fail] Insufficient light from Lamp detected in CCD. (During white gradation correction/AGC before Scan starts) [AGC Fail] Insufficient lamp brightness was detected when performing AGC.
Remedy: Check whether there is something blocking the light and check the Lamp, Lens, Mirror, and White Color Correction Plate for deterioration or contamination. 1. Turn ON the power and enter the Diag mode. Change the value for NVM [715-030] to '1' and then perform [NVM Write]. 2. A 3 or 4-digit number is displayed in the current value column. 3. Check the upper 1 or 2 digits, or the lower 2 digits using the following table and replace the appropriate parts. Sample Display • 110 (3-digit display): LED Lamp failure and LED Lamp Flexible Flat Cable is damaged or has poor contact. (The first digit '1' in '110' is the upper digit, which indicates the LED Lamp ('0' in '01' is not displayed). The lower 2 digits '10' indicates the LED Lamp Flexible Flat Cable.) • 1000 (4-digit display): The LED Lamp Flexible Flat Cable is damaged or has poor contact. (The first 2 digits '10' in '1000' are the upper digits, which indicates the LED Lamp Flexible Flat Cable. The lower 2 digits '00' indicates that nothing is applicable (no failures).) NOTE: Perform IIT diagnostic and then call NVM [715-030] again (press the Change Settings button) to check the value (diagnostic result). 4. After replacing the appropriate parts, again change the value for NVM [715-030] to '1' and then perform 'NVM Write'. 5. Check that the current value column becomes '0'. 6. If the problem persists after performing the above procedure, check the following: • Check for burnt out LED Lamp (DC330 [062-002]). (PL 1.5) • Check the Flat Cable between the LED Lamp PWB J7002 and the IIT Carriage J7001 for open circuits, short circuits, and poor contacts (especially, check whether the Flat Cable was inserted in a skewed manner). • Check the Flat Cable between the IIT Carriage J700 and the ESS/MCU PWB J420 for open circuits, short circuits, and poor contacts (especially, check whether the Flat Cable was inserted in a skewed manner). 7. If no problem is found, replace the ESS/MCU PWB. (PL 18.1)
Code: 062-386
Description: AOC Fail A CCD output error was detected when performing AOC.
Remedy: 1. Turn ON the power and enter the Diag mode. Change the value for NVM [715-030] to '1' and then perform [NVM Write]. 2. A 3 or 4-digit number is displayed in the current value column. 3. Check the upper 1 or 2 digits, or the lower 2 digits and replace the appropriate parts. (For more information on display example and part selection, refer to Procedure 3 in 062- 371 FIP.) NOTE: Perform IIT diagnostic and then call NVM [715-030] again (press the Change Settings button) to check the value (diagnostic result). 4. After replacing the appropriate parts, again change the value for NVM [715-030] to '1' and then perform 'NVM Write'. 5. Check that the current value column becomes '0'. 6. If the problem persists after performing the above procedure, check the Flat Cable between the IIT Carriage J700 and the ESS/MCU PWB J420 for open circuits, short circuits, and poor contacts (especially, check whether the Flat Cable was inserted in a skewed manner). 7. If no problem is found, replace the ESS/MCU PWB. (PL 18.1)
Code: 062-389
Description: Carriage Over Run Fail (Scan End Side) The Carriage has overrun at the Scan End.
Remedy: Check the following: • The Drive Belt and Drive Wire for slack and wear. • The Carriage operation for mechanical loading. • The Carriage Motor (Output Check [062-005/006] (Scan/Return)) for operation failure. (PL 1.4) • The IIT Regi. Sensor (Input Check [062-212]) for operation failure. (PL 1.3) If no problems are found, replace the ESS/MCU PWB. (PL 18.1)
Code: 062-396
Description: CCD Cable Connection Fail A CCD Flat Cable connection error was detected.
Remedy: 1. Turn the power OFF and ON. 2. Turn OFF the power and check the Flat Cable between the IIT Carriage J700 and the ESS/MCU PWB J420 for open circuits, short circuits, and poor contacts (especially, check whether the Flat Cable was inserted in a skewed manner). 3. If no problem is found, replace the following parts in sequence: • CCD Flexible Flat Cable (PL 1.3) • ESS/MCU PWB (PL 18.1)
Code: 071-105
Description: Regi Sensor On Jam (Tray 1) During paper feed from Tray 1, the Regi Sensor did not turn ON within the specified time after the Tray 1 Feed Clutch On.
Remedy: Check the following: • The Regi Sensor (Input Check [071-105]) for operation failure. (PL 15.1) • The Main Drive Motor (Output Check [042-001]) for operation failure. (PL 3.1) • The Tray 1 Feed Clutch (Output Check [072-001]) for operation failure. (PL 9.1) • The Feed Roll for contamination, wear, and transportation failure due to deterioration. • The Drive Gear for wear and damage. • A paper transportation failure due to foreign substances on the paper path. • Usage of out of spec paper. If no problems are found, replace the ESS/MCU PWB. (PL 18.1)
Code: 072-102
Description: Feed Out Sensor 2 On Jam During paper feed from Tray 2, the Feed Out Sensor 2 did not turn ON within the specified time after the Tray 2 Feed Motor On.
Remedy: Check the following: • The Feed Out Sensor 2 (Input Check [072-104]) for operation failure. (PL 10.5) • The STM Take Away Motor (Output Check [072-004]) for operation failure. (PL 10.6) • The STM Take Away Roll Clutch (Output Check [072-003]) for operation failure. (PL 10.6) • The Tray 2 Feed/Lift Up Motor (Output Check [072-002] (Feed)) for operation failure. (PL 10.3) • The T/A Roll 2, Feed Roll, Nudger Roll, and Pinch Roll for transportation failure due to contamination, wear, and deterioration. • The LH Cover for improper latching. • The Drive Gear for wear and damage. • A paper transportation failure due to foreign substances on the paper path. • Usage of out of spec paper. If no problem is found, replace the STM PWB. (PL 10.6)
Code: 072-105
Description: Regi Sensor On Jam (Tray 2) During paper feed from Tray 2, the Regi Sensor did not turn ON within the specified time after the Feed Out Sensor 2 On.
Remedy: Check the following: • The Regi Sensor (Input Check [071-105]) for operation failure. (PL 15.1) • The STM Take Away Motor (Output Check [072-004]) for operation failure. (PL 10.6) • The STM Take Away Roll Clutch (Output Check [072-003]) for operation failure. (PL 10.6) • The T/A Roll 2, Feed Roll, and Pinch Roll for transportation failure due to contamination, wear, and deterioration. • The Drive Gear for wear and damage. • A paper transportation failure due to foreign substances on the paper path. • Usage of out of spec paper. If no problem is found, replace the following parts in sequence: • ESS/MCU PWB (PL 18.1) • STM PWB (PL 10.6)