Description: Different Finisher Detected RAP BSD-ON: A Different type of Finisher connection was detected.
Remedy: Check the connection of each MCU PWB connector. The connectors are securely connected. Y↓N→Connect the connectors. Check the connection of each Duplex Module PWB connector. The connectors are securely connected. Y↓N→Connect the connectors. Check the wire between J417 and J540 for an open circuit or a short circuit. The wire between J417 and J540 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the MCU PWB P417-A1 (+) and GND (-). The voltage is approx. +5VDC. Y↓N→Replace the MCU PWB (PL 9.1). Replace the Duplex PWB (PL 8.1). If the problem persists, replace the MCU PWB (PL 9.1).
Code: 047-214
Description: MCU Duplex Module RAP Communication error occurred between the MCU PWB and the Duplex Module.
Remedy: Check the connection of each MCU PWB connector. The connectors are securely connected. Y↓N→Connect the connectors. Check the connection of each Duplex Module PWB connector. The connectors are securely connected. Y↓N→Connect the connectors. Check the wire between J417 and J540 for an open circuit or a short circuit. The wire between J417 and J540 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the MCU PWB P417-A1 (+) and GND (-). The voltage is approx. +5VDC. Y↓N→Replace the MCU PWB (PL 9.1). Replace the Duplex PWB (PL 8.1). If the problem persists, replace the MCU PWB (PL 9.1).
Code: 047-215
Description: MCU Exit Communication Error RAP Communication error occurred between the MCU PWB and the Exit Module.
Remedy: Check the connection of each MCU PWB connector. The connectors are securely connected. Y↓N→Connect the connectors. Check the connection of each Exit PWB connector. The connectors are securely connected. Y↓N→Connect the connectors. Check the wire between P/J421 and P/J431 for an open circuit or a short circuit. The wire between P/J421 and P/J431 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Replace the Exit PWB (PL 9.1) If the problem persists, replace the MCU PWB (PL 9.1).
Code: 047-216
Description: MCU Finisher Communication RAP A communication error occurred between the MCU PWB and the Finisher Module.
Remedy: Check the connection of each MCU PWB connector. The connectors are securely connected. Y↓N→Connect the connectors. Check the connection of each Finisher PWB connector. The connectors are securely connected. Y↓N→Connect the connectors. Check the wire between P/J416 and J8989 for an open circuit or a short circuit. The wire between P/J416 and J8989 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Replace the Finisher PWB (PL 23.16) If the problem persists, replace the MCU PWB (PL 9.1).
Code: 047-217
Description: MCU HCF Communication RAP A communication error occurred between the MCU PWB and the HCF Module.
Remedy: Check the connection of each MCU PWB connector. The connectors are securely connected. Y↓N→Connect the connectors. Check the connection of each HCF PWB connector. The connectors are securely connected. Y↓N→Connect the connectors. Check the wire between PF/JF03 and P/J410 for an open circuit or a short circuit. The wire between P/J416 and J8843 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Replace the HCF PWB () If the problem persists, replace the MCU PWB (PL 9.1).
Code: 061-315
Description: Start Of Scan RAP The light intensity of the LD2 does not reach the specified value
Remedy: Check the connections of P/J406 on the MCU PWB and P/J140 on the ROS Unit. Connections are connected correctly. Y↓N→Connect P/J406 and P/J140. Check the wires between J406 and J140 for an open circuit or a short circuit. The wires are conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Replace the ROS Unit (PL 3.1) If the problem persists, replace the MCU PWB (PL 9.1).
Code: 061-321
Description: ROS Motor RAP • The ROS Motor rotation speed does not reach the specified value within the specified time after the ROS Motor started rotating. • The light intensity of the LD1 does not reach the specified value.
Remedy: Check the connections of P/J406 on the MCU PWB and P/J140 on the ROS Unit. Connections are connected correctly. Y↓N→Connect P/J406 and P/J140. Check the connections of P/J160 and P/J170. P/J160 and P/J170 are connected correctly. Y↓N→Connect P/J160 and P/J170. Check the wire between J406 and J140 for an open circuit or a short circuit. The wire between J406 and J140 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Check the wire between J406 and J130 for an open circuit or a short circuit. The wire between J406 and J130 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Execute Component Control[061-200 ROS MOTOR ON]. The ROS Motor can be heard. Y↓N→Measure the voltage between the MCU PWB P406-10 (+) and GND (-). The voltage is +24VDC. Y↓N→Measure the voltage between the MCU PWB P400-1 (+) and GND (-). The voltage is +24VDC. Y↓N→Measure the voltage between the Power Unit P526-4 (+) and GND (-). The voltage is +24VDC. Y↓N→Replace the Power Unit (PL 9.1). Repair the open circuit between J526 and J400. Replace the MCU PWB (PL 9.1). Replace the ROS Unit (PL 3.1) If the problem persists, replace the MCU PWB (PL 9.1). Install the Xero/Developer Cartridge securely. Measure the voltage between the MCU PWB P406-2 (+) and GND (-). The voltage is +5VDC. Y↓N→Replace the MCU PWB (PL 9.1). Replace the ROS Unit (PL 3.1) If the problem persists, replace the MCU PWB (PL 9.1).
Code: 061-333
Description: ROS Fan Defect RAP ROS Fan rotation failure.
Remedy: Execute Component Control[042-003 ROS FAN ON].Check for noise in the rotation of the ROS Fan (PL 3.1). The ROS Fan is rotating. Y↓N→Measure the voltage between the MCU PWB P/J407-1 (+) and GND (-). The voltage is approx. +24VDC. Y↓N→Replace the MCU PWB (PL 9.1). Check the wire between J407 and J219 for an open circuit or a short circuit. The wire between J407 and J219 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Replace the ROS Fan (PL 3.1). Replace the MCU PWB (PL 9.1).