Description: IIT/IPS PWB EEPROM RAP The IPS EEPROM failed during the Read/Write operation.
Remedy: Check the connection of each IIT/IPS PWB connector. The connectors are securely connected. Y↓N→Connect the connectors. Switch on the power. The problem persists. Y↓N→Return to Service Call Procedures Replace the IIT/IPS PWB (PL 11.3).
Code: 062-277
Description: IIT/IPS PWB DADF PWB Communication RAP Transmission error occurred between the IIT/IPS PWB and the DADF PWB.
Remedy: Check the connection of each IIT/IPS PWB connector. The connectors are securely connected. Y↓N→Connect the connectors. Check the connection of each DADF PWB connector. The connectors are securely connected. Y↓N→Connect the connectors. Check the wire between P/J751 and P750, and between P/J752 and P750 for an open circuit or a short circuit. The wires between P/J751 and P750, and between P/J752 and P750 are conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Replace the IIT/IPS PWB (PL 11.3). If the problem persists, replace the DADF PWB (PL 15.3).
Code: 062-300
Description: Platen Interlock Open RAP The Platen Interlock is open
Remedy: Check opening/closing of the Platen Cover. The Platen Cover can be opened/closed. Y↓N→Reinstall the Platen Cover correctly. Check the installation of the Platen Angle Sensor. The Platen Angle Sensor is installed correctly. Y↓N→Install the Platen Angle Sensor correctly. Execute Component Control [062-301 Platen Angle Sensor]. Open and close the Platen Cover. The display changes. Y↓N→Check the connections of P/J725 and P/J722. P/J725 and P/J722 are connected correctly. Y↓N→Connect P/J725 and P/J722. Check the wire between J725 and J722 for an open circuit or a short circuit. The wire between J725 and J722 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the IIT/IPS PWB P722-B7 (+) and GND (-). The voltage is approx. +5VDC. Y↓N→Replace the IIT/IPS PWB (PL 11.3). Measure the voltage between the IIT/IPS PWB P722-B9 (+) and GND (-). Actuate the Platen Angle Sensor with paper. The voltage changes. Y↓N→Replace the Platen Angle Sensor (PL 11.4). Replace the Platen Angle Sensor (PL 13.4). Replace the IIT/IPS PWB (PL 11.3).
Code: 062-310
Description: IIT/IPS PWB Controller Communication RAP Transmission error occurred between the IIT/IPS PWB and the ESS PWB.
Remedy: Check the connection of each IIT/IPS PWB connector. The connectors are securely connected. Y↓N→Connect the connectors. Check the connection of each ESS PWB connector. The connectors are securely connected. Y↓N→Connect the connectors. Check the wire between P/J720, P/J7193 and P/J320 for an open circuit or a short circuit. The wire between J720, 719, and J320 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Replace the IIT/IPS PWB (PL 11.3). If the problem persists, replace the ESS PWB (PL 9.2).
Code: 062-311
Description: IIT/IPS Software RAP A software error was detected by the IIT/IPS PWB.
Remedy: Perform GP 8 Firmware version. The firmware is the latest version. Y↓N→Reload Software (ADJ 9.3.1). Replace the IIT/IPS PWB (PL 11.3).
Code: 062-345
Description: IIT/IPS Subsystem RAP The IPS EEPROM failed during a read/write operation.
Remedy: Check the connection of each IIT/IPS PWB connector. The connectors are securely connected. Y↓N→Connect the connectors. Switch on the power. The problem persists. Y↓N→Return to Service Call Procedures. Replace the IIT/IPS PWB (PL 11.3).
Code: 062-357
Description: CCD Fan Failure RAP CCD Fan Failure
Remedy: Remove the Platen Glass. Execute Component Control [062-017 CCD Fan]. The CCD Fan operates. Y↓N→Replace the CCD Fan (PL 6.4). Check CCD Fan connections and wiring for damage.
Code: 062-360
Description: Carriage Position RAP • An error occurred while counting the pulses of the Carriage Motor. • After the Carriage Motor turned On, the IIT Registration Sensor did not turn On within the specified time.
Remedy: Check the Carriage Rail for dirt or contamination or distortion. Dirt or contamination or distortion is found in the Carriage Rail. Y↓N→Clean the rails or correct the distortion (PL 11.4). Execute Component Control [062-212 IIT Registration Sensor]. Actuate the IIT Registration Sensor with paper. The display changes. Y↓N→Check the connections of P/J728 and P/J7193. P/J728 and P/J7193 are connected correctly. Y↓N→Connect P/J728 and P/J7193. Check the wire between J728 and J7193 for an open circuit or a short circuit. The wire between J728 and J7193 is conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the voltage between the IIT/IPS PWB P7193-B10 (+) and GND (-). The voltage is approx. +5VDC. Y↓N→Replace the IIT/IPS PWB (PL 11.3). Measure the voltage between the IIT/IPS PWB P7193-B12 (+) and GND (-). Actuate the IIT Registration Sensor (PL 11.4) with paper. The voltage changes. Y↓N→Replace the IIT Registration Sensor (PL 11.4). Replace the IIT/IPS PWB (PL 11.3). Alternately execute Component Control[062-005 Carriage Motor SCAN ON] and Component Control[062-006 Carriage Motor RETURN ON]. The Carriage Motor starts up. Y↓N→Check the connection P/J721. P/J721 is connected correctly. Y↓N→Connect P/J721. Check the wires on J721 for an open circuit or a short circuit. The wires on J721 are conducting without an open circuit or a short circuit. Y↓N→Repair the open circuit or short circuit. Measure the resistance of the Carriage Motor (PL 11.5). The resistance between J721- 1/2 and J721-3/4/5/6 is approx. 1Ohm. Y↓N→Replace the Carriage Motor (PL 11.5). Measure the voltage between the IIT/IPS PWB (PL 11.3) P721-1/2 (+) and GND (-). The voltage is approx. +24VDC. Y↓N→Replace the IIT/IPS PWB (PL 11.3). Replace the Carriage Motor (PL 11.5) If the problem persists, replace the IIT/IPS PWB (PL 11.3). Replace the IIT/IPS PWB (PL 11.3).