Các lỗi thường gặp

Code :
  • Code: 062-300
  • Description: Platen Interlock Open RAP The Platen Interlock is open. NOTE: When turning the power OFF, turn OFF the power switch first and then the main power switch.
  • Remedy: Check the following: • The DADF for improper closing. • The Platen Close Sensor for failure: Component Control [062-300] (PL 1.3). • The connection between the Platen Close Sensor P/J7251 and the IIT PWB P/J722 for open circuit, short circuit, and poor contact • The connection between the IIT PWB P/J7192-30 and the ESS PWB P/J390-11 for open circuit, short circuit, and poor contact If no problems are found, replace the following parts in sequence: • Reload the machine software (GP 16). • ESS PWB (PL 35.2) • IIT PWB (Switch the EEPROM) (PL 1.6)
  • Code: 062-311
  • Description: IIT Software Logic Fail RAP A software error was detected at the ESS PWB. NOTE: When turning the power OFF, turn OFF the power switch first and then the main power switch.
  • Remedy: 1. Turn the power ON and enter the Diag mode. Change the value for NVM location [715- 030] to "1" and then execute NVM Write. 2. A 3 or 4-digit number is displayed in the current value column. 3. Check the upper 1 or 2 digits, or the lower 2 digits using the following table and replace the appropriate parts. Sample Display • 110 (3-digit display): LED Lamp PWB failure and LED Lamp Flexible Flat Cable is damaged or has poor contact. (The first digit "1" in "110" is the upper digit, which indicates the LED Lamp PWB ("0" in "01" is not displayed). The lower 2 digits "10" indicates the LED Lamp Flexible Flat Cable.) • 1000 (4-digit display): The LED Lamp Flexible Flat Cable is damaged or has poor contact. (The first 2 digits "10" in "1000" are the upper digits, which indicates the LED Lamp Flexible Flat Cable. The lower 2 digits "00" indicates that nothing is applicable (no failures). NOTE: Execute the IIT diagnosis and then call NVM location [715-030] again (press the Change Settings button) to check the value (diagnosis result).
    00 Not applicable (No errors) - 01 LED Lamp PWB PL 1.4 02 CCD Lens Assembly PL 1.2 03 CCD Flexible Flat Cable PL 1.2 10 LED Lamp Flexible Flat Cable PL 1.4 12 IIT-ESS Video Cable PL 18.4 14 IIT-ESS I/O Cable PL 18.4 17 LVPS-IIT/Fax Power Cable (DC Harness) PL 18.4
    4. After replacing the appropriate parts, again change the value for NVM location [715-030] to "1" and then execute "NVM Write". 5. Check that the current value column becomes "000". 6. If the problem persists, reload the machine software (GP 16).
  • Code: 062-360
  • Description: Carriage Position Fail RAP The Carriage position error was detected. NOTE: When turning the power OFF, turn OFF the power switch first and then the main power switch.
  • Remedy: Does the Carriage moves smoothly, with no interference? Y↓N→Check the Carriage operation for mechanical load, the Carriage Cable for winding failure, the Rail for contamination/foreign substances, and the Full Rate/Half Rate Carriage for improper position (ADJ 6.2), etc. Turn the power ON and enter the Diag mode. Turn ON Component Control [062-005] (Scan) or [062-006] (Return). Does the Carriage move? Y↓N→Turn the power OFF and check the following: • The connection between the Carriage Motor P/J7258 and the IIT PWB P/J721 for open circuit, short circuit, and poor contact • The coaxial cable between the IIT PWB P/J7191 and the ESS PWB P/J336 for open circuit, short circuit, and poor contact • The connection between the IIT PWB P/J7192 and the ESS PWB P/J390 for open circuit, short circuit, and poor contact If no problems are found, replace the following parts in sequence: • IIT PWB (Switch the EEPROM) (PL 1.6) • Carriage Motor (PL 1.6) • ESS PWB (PL 35.2) Press the Stop button. Turn ON Component Control [062-212] (IIT Registration Sensor). Manually move the Carriage and turn the IIT Registration Sensor ON then OFF. Does the display change between High/Low? Y↓N→Use OF 99-2 RAP to check the IIT Registration Sensor. It can be considered that there were no errors. Again, check the Carriage operation, check for any noise source around the machine and check for any abnormal electrical discharge, etc. If the problem occurs frequently, replace the following parts in sequence: • If the problem persists, reload the machine software (GP 16). • ESS PWB (PL 35.2) • IIT PWB (Switch the EEPROM) (PL 1.6)
  • Code: 062-371
  • Description: Lamp Illumination Fail RAP Insufficient light from Lamp detected in CCD. (During white gradation correction/AGC before Scan starts) NOTE: When turning the power OFF, turn OFF the power switch first and then the main power switch.
  • Remedy: Procedure 1. Turn the power ON and enter the Diag mode. Change the value for NVM location [715- 030] to "1" and then execute "NVM Write". 2. A 3 or 4-digit number is displayed in the current value column. 3. Check the upper 1 or 2 digits, or the lower 2 digits using the following table and replace the appropriate parts. Sample Display • 110 (3-digit display): LED Lamp PWB failure and LED Lamp Flexible Flat Cable is damaged or has poor contact. (The first digit "1" in "110" is the upper digit, which indicates the LED Lamp PWB ("0" in "01" is not displayed). The lower 2 digits "10" indicates the LED Lamp Flexible Flat Cable.) • 1000 (4-digit display): The LED Lamp Flexible Flat Cable is damaged or has poor contact. (The first 2 digits "10" in "1000" are the upper digits, which indicates the LED Lamp Flexible Flat Cable. The lower 2 digits "00" indicates that nothing is applicable (no failures).) NOTE: Execute the IIT diagnosis and then call NVM location [715-030] again (press the Change Settings button) to check the value (diagnosis result).
    00 Not applicable (No errors) - 01 LED Lamp PWB PL 1.4 02 CCD Lens Assembly PL 1.2 03 CCD Flexible Flat Cable PL 1.2 10 LED Lamp Flexible Flat Cable PL 1.4 12 IIT-ESS Video Cable PL 18.4 14 IIT-ESS I/O Cable PL 18.4 17 LVPS-IIT/Fax Power Cable (DC Harness) PL 18.4
    4. After replacing the appropriate parts, again change the value for NVM location [715-030] to "1" and then execute "NVM Write". 5. Check that the current value column becomes "000". 6. If the problem persists after performing the above procedure, continue and check the following: • LED Lamp broken: Component Control [062-002] (PL 1.2) • Check the Flat Cable between the LED Lamp PWB P/J7001 and the IIT PWB P/ J723 for open circuits, short circuits, and poor contacts (especially, check whether the Flat Cable was inserted in a skewed manner). • Check the Flat Cable between the CCD Lens Assembly P/J700 and the IIT PWB P/ J710 for open circuits, short circuits, and poor contacts (especially, check whether the Flat Cable was inserted in a skewed manner). • The coaxial cable between the IIT PWB P/J7191 and the ESS PWB P/J336 for open circuit, short circuit, and poor contact
  • Code: 062-380
  • Description: Platen AGC Fail RAP Insufficient lamp brightness was detected when performing AGC. NOTE: When turning the power OFF, turn OFF the power switch first and then the main power switch.
  • Remedy: 1. Turn the power ON and enter the Diag mode. Change the value for NVM location [715- 030] to "1" and then execute "NVM Write". 2. A 3 or 4-digit number is displayed in the current value column. 3. Check the upper 1 or 2 digits, or the lower 2 digits using the following table and replace the appropriate parts. Sample Display • 110 (3-digit display): LED Lamp PWB failure and LED Lamp Flexible Flat Cable is damaged or has poor contact. (The first digit "1" in "110" is the upper digit, which indicates the LED Lamp PWB ("0" in "01" is not displayed). The lower 2 digits "10" indicates the LED Lamp Flexible Flat Cable.) • 1000 (4-digit display): The LED Lamp Flexible Flat Cable is damaged or has poor contact. (The first 2 digits "10" in "1000" are the upper digits, which indicates the LED Lamp Flexible Flat Cable. The lower 2 digits "00" indicates that nothing is applicable (no failures).) NOTE: Execute the IIT diagnosis and then call NVM location [715-030] again (press the Change Settings button) to check the value (diagnosis result).
    00 Not applicable (No errors) - 01 LED Lamp PWB PL 1.4 02 CCD Lens Assembly PL 1.2 03 CCD Flexible Flat Cable PL 1.2 10 LED Lamp Flexible Flat Cable PL 1.4 12 IIT-ESS Video Cable PL 18.3 14 IIT-ESS I/O Cable PL 18.3 17 LVPS-IIT/Fax Power Cable (DC Harness) PL 18.3
    4. After replacing the appropriate parts, again change the value for NVM location [715-030] to "1" and then execute "NVM Write". 5. Check that the current value column becomes "000". 6. If the problem persists after performing the above procedure, continue and check the following: • LED Lamp broken: Component Control [062-002] (PL 1.2) • Check the Flat Cable between the LED Lamp PWB P/J7001 and the IIT PWB P/ J723 for open circuits, short circuits, and poor contacts (especially, check whether the Flat Cable was inserted in a skewed manner). • Check the Flat Cable between the CCD Lens Assembly P/J700 and the IIT PWB P/ J710 for open circuits, short circuits, and poor contacts (especially, check whether the Flat Cable was inserted in a skewed manner). • The coaxial cable between the IIT PWB P/J7191 and the ESS PWB P/J336 for open circuit, short circuit, and poor contact
  • Code: 062-386
  • Description: Platen AOC Fail RAP A CCD output error was detected when performing AOC. NOTE: When turning the power OFF, turn OFF the power switch first and then the main power switch.
  • Remedy: 1. Turn the power ON and enter the Diag mode. Change the value for NVM location [715- 030] to "1" and then execute "NVM Write". 2. A 3 or 4-digit number is displayed in the current value column. 3. Check the upper 1 or 2 digits, or the lower 2 digits using the following table and replace the appropriate parts. Sample Display • 110 (3-digit display): LED Lamp PWB failure and LED Lamp Flexible Flat Cable is damaged or has poor contact. (The first digit "1" in "110" is the upper digit, which indicates the LED Lamp PWB ("0" in "01" is not displayed). The lower 2 digits "10" indicates the LED Lamp Flexible Flat Cable.) • 1000 (4-digit display): The LED Lamp Flexible Flat Cable is damaged or has poor contact. (The first 2 digits "10" in "1000" are the upper digits, which indicates the LED Lamp Flexible Flat Cable. The lower 2 digits "00" indicates that nothing is applicable (no failures).) NOTE: Execute the IIT diagnosis and then call NVM location [715-030] again (press the Change Settings button) to check the value (diagnosis result).
    00 Not applicable (No errors) - 01 LED Lamp PWB PL 1.4 02 CCD Lens Assembly PL 1.2 03 CCD Flexible Flat Cable PL 1.2 10 LED Lamp Flexible Flat Cable PL 1.4 12 IIT-ESS Video Cable PL 18.3 14 IIT-ESS I/O Cable PL 18.3 17 LVPS-IIT/Fax Power Cable (DC Harness) PL 18.3
    4. After replacing the appropriate parts, again change the value for NVM location [715-030] to "1" and then execute "NVM Write". 5. Check that the current value column becomes "000". 6. If the problem persists after performing the above procedure, check the following: • Check the Flat Cable between the CCD Lens Assembly P/J700 and the IIT PWB P/ J710 for open circuits, short circuits, and poor contacts (especially, check whether the Flat Cable was inserted in a skewed manner). • The coaxial cable between the IIT PWB P/J7191 and the ESS PWB P/J336 for open circuit, short circuit, and poor contact If no problems are found, replace the following parts in sequence: • CCD Lens Assembly (PL 1.2) • ESS PWB (PL 35.2) • IIT PWB (Switch the EEPROM) (PL 1.6)
  • Code: 062-389
  • Description: Carriage Over Run Fail RAP The Carriage has overrun at the Scan End.
  • Remedy: Remove the Platen Glass and move the Full Rate Carriage to right and left manually. Does the Carriage moves smoothly, with no interference? Y↓N→Check the Carriage operation for mechanical load, the Carriage Cable for winding failure, the Rail for contamination/foreign substances, and the Full Rate/Half Rate Carriage for improper position (ADJ 6.2), etc. Turn the power ON and enter the Diag mode. Turn ON Component Control [062-005] (Scan) or [062-006] (Return). Does the Carriage move? Y↓N→Turn the power OFF and check the following: • The connection between the Carriage Motor P/J7258 and the IIT PWB P/J721 for open circuit, short circuit, and poor contact • The coaxial cable between the IIT PWB P/J7191 and the ESS PWB P/J336 for open circuit, short circuit, and poor contact • The connection between the IIT PWB P/J7192 and the ESS PWB P/J390 for open circuit, short circuit, and poor contact If no problems are found, replace the following parts in sequence: • IIT PWB (Switch the EEPROM) (PL 1.6) • Carriage Motor (PL 1.6) • ESS PWB (PL 35.2) Press the Stop button. Turn ON Component Control [062-212] (IIT Registration Sensor). Manually move the Carriage and turn the IIT Registration Sensor ON then OFF. Does the display change between High/Low? Y↓N→Use OF 99-2 RAP to check the IIT Registration Sensor. It can be considered that there were no errors. Again, check the Carriage operation, check for any noise source around the machine and check for any abnormal electrical discharge, etc. If the problem occurs frequently, replace the following parts in sequence: • If the problem persists, reload the machine software (GP 16). • ESS PWB (PL 35.2) • IIT PWB (Switch the EEPROM) (PL 1.6)
  • Code: 062-393
  • Description: CCD PWB Sync Signal Fail RAP • Write failure to the Shading Memory has occurred. • Averaging processing error has occurred in the ASIC.
  • Remedy: 1. Turn the power ON and enter the Diag mode. Change the value for NVM location [715- 030] to "1" and then execute "NVM Write". 2. A 3 or 4-digit number is displayed in the current value column. 3. Check the upper 1 or 2 digits, or the lower 2 digits using the following table and replace the appropriate parts. Sample Display • 110 (3-digit display): LED Lamp PWB failure and LED Lamp Flexible Flat Cable is damaged or has poor contact. (The first digit "1" in "110" is the upper digit, which indicates the LED Lamp PWB ("0" in "01" is not displayed). The lower 2 digits "10" indicates the LED Lamp Flexible Flat Cable.) • 1000 (4-digit display): The LED Lamp Flexible Flat Cable is damaged or has poor contact. (The first 2 digits "10" in "1000" are the upper digits, which indicates the LED Lamp Flexible Flat Cable. The lower 2 digits "00" indicates that nothing is applicable (no failures).) NOTE: Execute the IIT diagnosis and then call NVM location[715-030] again (press the Change Settings button) to check the value (diagnosis result).
    00 Not applicable (No errors) - 01 LED Lamp PWB PL 1.4 02 CCD Lens Assembly PL 1.2 03 CCD Flexible Flat Cable PL 1.2 10 LED Lamp Flexible Flat Cable PL 1.4 12 IIT-ESS Video Cable PL 18.3 14 IIT-ESS I/O Cable PL 18.3 17 LVPS-IIT/Fax Power Cable (DC Harness) PL 18.3
    4. After replacing the appropriate parts, again change the value for NVM location [715-030] to "1" and then execute "NVM Write". 5. Check that the current value column becomes "000". 6. If the problem persists after performing the above procedure, check the following: • Check the Flat Cable between the CCD Lens Assembly P/J700 and the IIT PWB P/ J710 for open circuits, short circuits, and poor contacts (especially, check whether the Flat Cable was inserted in a skewed manner). • The coaxial cable between the IIT PWB P/J7191 and the ESS PWB P/J336 for open circuit, short circuit, and poor contact If no problems are found, replace the following parts in sequence: • If the problem persists, reload the machine software (GP 16). • ESS PWB (PL 35.2) • IIT PWB (Switch the EEPROM) (PL 1.6)