Description: Cyan TCR Sensor adjustment failure - TCR Sensor automatic adjustment does not function properly, failing to adjust to an appropriate value.
Causes: • Photoconductor Unit /C • Photoconductor Unit /M • Photoconductor Unit /Y • Toner Supply Motor Y/M (M6) • Toner Supply Motor C/K (M7) • Mechanical Control Board (PWB-M) • Controller Board (PWB-P)
Remedy: 1 Clean the TCR Sensor window on the underside of the Photoconductor Unit if dirty - - 2 M6, M7 operation check PWB-M CNDM2-10 to 13 (M6) PWB-M CNDM3-10 to 13 (M7) C-22 C-23 3 Reinstall Photoconductor Unit - - 4 Change Photoconductor Unit - - 5 Change PWB-M - - 6 Change PWB-P
Description: Magenta TCR Sensor adjustment failure - TCR Sensor automatic adjustment does not function properly, failing to adjust to an appropriate value.
Causes: • Photoconductor Unit /C • Photoconductor Unit /M • Photoconductor Unit /Y • Toner Supply Motor Y/M (M6) • Toner Supply Motor C/K (M7) • Mechanical Control Board (PWB-M) • Controller Board (PWB-P)
Remedy: 1 Clean the TCR Sensor window on the underside of the Photoconductor Unit if dirty - - 2 M6, M7 operation check PWB-M CNDM2-10 to 13 (M6) PWB-M CNDM3-10 to 13 (M7) C-22 C-23 3 Reinstall Photoconductor Unit - - 4 Change Photoconductor Unit - - 5 Change PWB-M - - 6 Change PWB-P
Description: Yellow TCR Sensor adjustment failure - TCR Sensor automatic adjustment does not function properly, failing to adjust to an appropriate value.
Causes: • Photoconductor Unit /C • Photoconductor Unit /M • Photoconductor Unit /Y • Toner Supply Motor Y/M (M6) • Toner Supply Motor C/K (M7) • Mechanical Control Board (PWB-M) • Controller Board (PWB-P)
Remedy: 1 Clean the TCR Sensor window on the underside of the Photoconductor Unit if dirty - - 2 M6, M7 operation check PWB-M CNDM2-10 to 13 (M6) PWB-M CNDM3-10 to 13 (M7) C-22 C-23 3 Reinstall Photoconductor Unit - - 4 Change Photoconductor Unit - - 5 Change PWB-M - - 6 Change PWB-P
Description: Black TCR Sensor adjustment failure - TCR Sensor automatic adjustment does not function properly, failing to adjust to an appropriate value.
Causes: • Photoconductor Unit /K • Toner Supply Motor C/K (M7) • Mechanical Control Board (PWB-M) • Controller Board (PWB-P)
Remedy: 1 Clean or correct each contact of the Photoconductor Unit if faulty. - - 2 M7 operation check PWB-M CNDM3-10 to 13 C-23 3 Reinstall Photoconductor Unit /K - - 4 Change Photoconductor Unit /K - - 5 Change PWB-M - - 6 Change PWB-P
Description: 1st Image Transfer ATVC (color) failure - An abnormal average value is detected while performing the first image transfer ATVC of color.
Causes: • Transfer Belt Unit • Transfer Roller • High Voltage Unit
Remedy: 1 Check if the Transfer Roller and Transfer Belt are dirty and correct as necessary. - - 2 Change High Voltage Unit - - 3 Change Transfer Belt Unit
Description: 1st Image Transfer ATVC (K) failure - An abnormal average value is detected while performing the first image transfer ATVC of black.
Causes: • Transfer Belt Unit • High Voltage Unit
Remedy: 1 Check if the Transfer Roller and Transfer Belt are dirty and correct as necessary. - - 2 Change High Voltage Unit - - 3 Change Transfer Belt Unit
Description: 2nd Image Transfer ATVC failure - An abnormal average value is detected while performing the second image transfer ATVC.
Causes: • Transfer Belt Unit • 2nd Transfer Roller • High Voltage Unit
Remedy: 1 Check if the Transfer Roller and Transfer Belt are dirty and correct as necessary. - - 2 Check that the 2nd Transfer Roller is properly installed and correct as necessary. - - 3 Change 2nd Transfer Roller. - - 4 Change High Voltage Unit.
Description: Color PC Drum sensor malfunction - The output from the Color PC Drive Main and Sub Sensors remains unchanged for a continuous period of 1,000 ms while the Color PC Drum Motor is turning stably and the Lock signal is active (LOW-0).
Causes: • Transport Drive Assy • Mechanical Control Board (PWB-M) • Harness
Remedy: 1 Check if the Detect Light Shield Plate has damages and is properly installed, and correct as necessary. - - 2 Check the Transport Drive Assy connector for proper connection and correct as necessary. - - 3 Check the PWB-M connector for proper connection and correct as necessary. - - 4 Change the cable that connects Transport Drive Assy and PWB-M. - - 5 Change Transport Drive Assy - - 6 Change PWB-M
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.