Description: Cyan TCR Sensor adjustment failure - TCR Sensor automatic adjustment does not function properly, failing to adjust to an appropriate value.
Causes: • Photoconductor Unit /C • Photoconductor Unit /M • Photoconductor Unit /Y • Toner Supply Motor Y/M (M6) • Toner Supply Motor C/K (M7) • Mechanical Control Board (PWB-M) • Controller Board (PWB-P)
Remedy: 1 Clean the TCR Sensor window on the underside of the Photoconductor Unit if dirty - - 2 M6, M7 operation check PWB-M CNDM2-10 to 13 (M6) PWB-M CNDM3-10 to 13 (M7) C-22 C-23 3 Reinstall Photoconductor Unit - - 4 Change Photoconductor Unit - - 5 Change PWB-M - - 6 Change PWB-P
Code: E601
Description: Magenta TCR Sensor adjustment failure - TCR Sensor automatic adjustment does not function properly, failing to adjust to an appropriate value.
Causes: • Photoconductor Unit /C • Photoconductor Unit /M • Photoconductor Unit /Y • Toner Supply Motor Y/M (M6) • Toner Supply Motor C/K (M7) • Mechanical Control Board (PWB-M) • Controller Board (PWB-P)
Remedy: 1 Clean the TCR Sensor window on the underside of the Photoconductor Unit if dirty - - 2 M6, M7 operation check PWB-M CNDM2-10 to 13 (M6) PWB-M CNDM3-10 to 13 (M7) C-22 C-23 3 Reinstall Photoconductor Unit - - 4 Change Photoconductor Unit - - 5 Change PWB-M - - 6 Change PWB-P
Code: E602
Description: Yellow TCR Sensor adjustment failure - TCR Sensor automatic adjustment does not function properly, failing to adjust to an appropriate value.
Causes: • Photoconductor Unit /C • Photoconductor Unit /M • Photoconductor Unit /Y • Toner Supply Motor Y/M (M6) • Toner Supply Motor C/K (M7) • Mechanical Control Board (PWB-M) • Controller Board (PWB-P)
Remedy: 1 Clean the TCR Sensor window on the underside of the Photoconductor Unit if dirty - - 2 M6, M7 operation check PWB-M CNDM2-10 to 13 (M6) PWB-M CNDM3-10 to 13 (M7) C-22 C-23 3 Reinstall Photoconductor Unit - - 4 Change Photoconductor Unit - - 5 Change PWB-M - - 6 Change PWB-P
Code: E603
Description: Black TCR Sensor adjustment failure - TCR Sensor automatic adjustment does not function properly, failing to adjust to an appropriate value.
Causes: • Photoconductor Unit /K • Toner Supply Motor C/K (M7) • Mechanical Control Board (PWB-M) • Controller Board (PWB-P)
Remedy: 1 Clean or correct each contact of the Photoconductor Unit if faulty. - - 2 M7 operation check PWB-M CNDM3-10 to 13 C-23 3 Reinstall Photoconductor Unit /K - - 4 Change Photoconductor Unit /K - - 5 Change PWB-M - - 6 Change PWB-P
Code: E610
Description: 1st Image Transfer ATVC (color) failure - An abnormal average value is detected while performing the first image transfer ATVC of color.
Causes: • Transfer Belt Unit • Transfer Roller • High Voltage Unit
Remedy: 1 Check if the Transfer Roller and Transfer Belt are dirty and correct as necessary. - - 2 Change High Voltage Unit - - 3 Change Transfer Belt Unit
Code: E611
Description: 1st Image Transfer ATVC (K) failure - An abnormal average value is detected while performing the first image transfer ATVC of black.
Causes: • Transfer Belt Unit • High Voltage Unit
Remedy: 1 Check if the Transfer Roller and Transfer Belt are dirty and correct as necessary. - - 2 Change High Voltage Unit - - 3 Change Transfer Belt Unit
Code: E612
Description: 2nd Image Transfer ATVC failure - An abnormal average value is detected while performing the second image transfer ATVC.
Causes: • Transfer Belt Unit • 2nd Transfer Roller • High Voltage Unit
Remedy: 1 Check if the Transfer Roller and Transfer Belt are dirty and correct as necessary. - - 2 Check that the 2nd Transfer Roller is properly installed and correct as necessary. - - 3 Change 2nd Transfer Roller. - - 4 Change High Voltage Unit.
Code: E620
Description: Color PC Drum sensor malfunction - The output from the Color PC Drive Main and Sub Sensors remains unchanged for a continuous period of 1,000 ms while the Color PC Drum Motor is turning stably and the Lock signal is active (LOW-0).
Causes: • Transport Drive Assy • Mechanical Control Board (PWB-M) • Harness
Remedy: 1 Check if the Detect Light Shield Plate has damages and is properly installed, and correct as necessary. - - 2 Check the Transport Drive Assy connector for proper connection and correct as necessary. - - 3 Check the PWB-M connector for proper connection and correct as necessary. - - 4 Change the cable that connects Transport Drive Assy and PWB-M. - - 5 Change Transport Drive Assy - - 6 Change PWB-M