Code: E621

Description: BLACK PC Drum sensor malfunction
- The output from the Black PC Drive Main and Sub Sensors remains unchanged for a continuous period of 1,000 ms while the Main Motor is turning stably and the Lock signal is active (LOW-0).
Causes: • Transport Drive Assy • Mechanical Control Board (PWB-M) • Harness
Remedy: 1 Check if the Detect Light Shield Plate has damages and is properly installed, and correct as necessary. - - 2 Check the Transport Drive Assy connector for proper connection and correct as necessary. - - 3 Check the PWB-M connector for proper connection and correct as necessary. - - 4 Change the cable that connects Transport Drive Assy and PWB-M. - - 5 Change Transport Drive Assy - - 6 Change PWB-M

Code: E630

Description: IDC Sensor (front) failure
- All outputs of Sensor photo-receiver section from the detection point (unprinted surface on the Image Transfer Belt) are 0.5 V or less, or 4.3 V or more at output checking during IDC Sensor adjustment.
- All outputs of Sensor photo-receiver section from the detection point (unprinted surface on the Image Transfer Belt) are 1.9 V or less, or 4.4 V or more at density setting during IDC Sensor adjustment.
- The output of Sensor photo-receiver section from the detection point (toner pattern on the Image Transfer Belt) is 1.0 V or less after the adjustment.
Causes: IDC Sensor
Remedy: 1 Check that the IDC Sensor is properly installed and correct as necessary. - - 2 Check if the IDC sensor is dirty and correct as necessary. - - 3 Check the IDC Sensor connector for proper connection and correct as necessary. - - 4 Check the PWB-M connector for proper connection and correct as necessary. - - 5 Change the cable that connects IDC Sensor and PWB-M. - - 6 Change the IDC Sensor.

Code: E631

Description: IDC Sensor (back) failure
- All outputs of Sensor photo-receiver section from the detection point (unprinted surface on the Image Transfer Belt) are 0.5 V or less, or 4.3 V or more at output checking during IDC Sensor adjustment.
- All outputs of Sensor photo-receiver section from the detection point (unprinted surface on the Image Transfer Belt) are 1.9 V or less, or 4.4 V or more at density setting during IDC Sensor adjustment.
- The output of Sensor photo-receiver section from the detection point (toner pattern on the Image Transfer Belt) is 1.0 V or less after the adjustment.
Causes: IDC Sensor
Remedy: 1 Check that the IDC Sensor is properly installed and correct as necessary. - - 2 Check if the IDC sensor is dirty and correct as necessary. - - 3 Check the IDC Sensor connector for proper connection and correct as necessary. - - 4 Check the PWB-M connector for proper connection and correct as necessary. - - 5 Change the cable that connects IDC Sensor and PWB-M. - - 6 Change the IDC Sensor.

Code: E640

Description: Color Shift Test Pattern failure
- The number of points detected in the main scan direction is more or less than the specified value during main scan direction registration correction.
- The number of points detected in the sub scan direction is more or less than the specified value during sub scan direction registration correction.
Causes: • Transfer Belt Unit • IDC Sensor • Photoconductor Unit • PH Unit
Remedy: 1 Check if Transfer Belt has damages and correct as necessary. - - 2 Check that the IDC Sensor is properly installed and correct as necessary. - - 3 Check if the IDC sensor is dirty and correct as necessary. - - 4 Check the IDC Sensor connector for proper connection and correct as necessary. - - 5 Check the PWB-M connector for proper connection and correct as necessary. - - 6 Change the cable that connects IDC Sensor and PWB-M. 7 Change IDC Sensor. 8 Change Photoconductor Unit. 9 Change PH Unit.

Code: E641

Description: Color Shift Adjust failure
- The color shift amount is greater than the specified range during main scan direction registration correction.
- The color shift amount is greater than the specified range during sub scan direction registration correction.
- The skew correction amount is greater than the specified value.
Causes: • PH Unit (displacement) • Transfer Belt Unit
Remedy: 1 Execute the correction of skew. - - 2 Check if Transfer Belt has damages and correct as necessary.

Code: E701

Description: MP tray Rise Descent Error
- The Bypass Lift-Up Sensor is not blocked even when the Vertical Transport Motor has turned for a given number of pulses after the sequence to move the Paper Lifting Plate from the standby position to the feed position was started.
- The Bypass Lift-Up Sensor is not unblocked even when the Vertical Transport Motor has turned for a given number of pulses after the sequence to move the Paper Lifting Plate from the feed position to the standby position was started.
Causes: • MP tray Lift-up Sensor (PC14) • Vertical Transport Motor (M2-PC) • Control Board (PWB-Z-PC)
Remedy: 1 Check the M2-PC connector for proper connection and correct as necessary. - - 2 Check the connector of M2-PC for proper drive coupling and correct as necessary. - - 3 PC14 I/O check, Sensor check PWB-M CNTRY1-10 (ON) C-10 4 M2-PC operation check PWB-Z PJ5Z PC-5~8 Q-22 5 Change PWB-Z-PC.

Code: E702

Description: Standard cassette Elevator failure
- The Lift-Up Sensor is not blocked even after the lapse of a given period of time after the lifting motion has been started.
Causes: • Lift-up Sensor (PC7-PC) • Lift-up Sensor (PC7-PC) • Control Board (PWB-Z-PC)
Remedy: 1 Check the M3-PC connector for proper connection and correct as necessary. - - 2 Check the connector of M3-PC for proper drive coupling and correct as necessary. - - 3 PC7-PC I/O check, Sensor check PWB-Z PJ6Z PC-3 (ON) PWB-Z PJ4Z PC-4 to 5 V-21 to 22 4 M3-PC operation check Q-24 5 Change PWB-Z-PC.

Code: E703

Description: Optional Cassette1 Elevator failure
- The Lift-Up Sensor is not blocked even after the lapse of a given period of time after the lifting motion has been started.
Causes: • Lift-up Sensor (PC7-PC) • Lift-up Sensor (PC7-PC) • Control Board (PWB-Z-PC)
Remedy: 1 Check the M3-PC connector for proper connection and correct as necessary. - - 2 Check the connector of M3-PC for proper drive coupling and correct as necessary. - - 3 PC7-PC I/O check, Sensor check PWB-Z PJ6Z PC-3 (ON) PWB-Z PJ4Z PC-4 to 5 V-21 to 22 4 M3-PC operation check Q-24 5 Change PWB-Z-PC.