Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi HP DesignJet 10000s — Trang 7/7

Code: H05

Description: Center Heater Temperature Error
Temperature read by the Center Heater is abnormal (lower than -10C or higher than 70C).
Remedy: • Make sure that the Heater Relay Assembly is connected correctly to the Center Platen. • Replace the Heater Relay Assembly • Replace the Center Platen

Code: H06

Description: Front Heater Time-out Error
The temperature of the Front Heater does not reach the preset temperature even after 15 minutes.
Remedy: • Make sure that the Voltage alternation switch located at the back of the Printer is set correctly to the AC voltage being used. • Make sure that the Fuse (F2) on the Heater Relay Assembly has not blown. If the fuse has blown, replace it. • Make sure that the Heater Board is connected correctly to the Relay Board via the Relay Cable. • Make sure that the Heater Relay Assembly is connected correctly to the Front Heater. • Replace the Heater Relay Assembly • Replace the Front Heater

Code: H07

Description: Rear Heater Time-out Error
The temperature of the Rear Heater does not reach the preset temperature even after 15 minutes.
Remedy: • Make sure that the Voltage alternation switch located at the back of the Printer is set correctly to the AC voltage being used. • Make sure that the Fuse (F2) on the Heater Relay Assembly has not blown. If the fuse has blown, replace it. • Make sure that the Heater Board is connected correctly to the Relay Board via the Relay Cable. • Make sure that the Heater Relay Assembly is connected correctly to the Rear Heater. • Replace the Heater Relay Assembly • Replace the Rear Heater

Code: H08

Description: Center Heater Time-out Error
The temperature of the Center Heater does not reach the preset temperature even after 15 minutes.
Remedy: • Make sure that the Voltage alternation switch located at the back of the Printer is set correctly to the AC voltage being used. • Make sure that the Fuse (F2) on the Heater Relay Assembly has not blown. If the fuse has blown, replace it. • Make sure that the Heater Board is connected correctly to the Relay Board via the Relay Cable. • Make sure that the Heater Relay Assembly is connected correctly to the Center Platen. • Replace the Heater Relay Assembly • Replace the Center Platen Heater

Code: H09

Description: Operation Panel Switch Error
The specified switch is not pressed for 30 seconds or more when the diagnostics that verifies the switch action is executed.
Remedy: • Replace the Heater Relay Assembly

Code: H10

Description: Zero Cross Error
This error occurs when the diagnostics for the AC Relay is executed.
Remedy: • Make sure that the Heater Board is connected correctly to the relays on the Heater Block Assembly • Make sure that the Heater Board is connected correctly to the Relay Board via the Relay Cable. • Replace the Heater Relay Assembly