Các lỗi thường gặp

Code :
  • Code: 0100
  • Description: ASIC CONF (Carriage PCA)
    The program load from the Flash ROM on the Main PCA to the ASIC on the Carriage PCA or sum-check was not performed correctly and an error occurred.
  • Remedy: • Reload the ASIC program from the IC Card. • Make sure that the Carriage Cable is correctly connected. • Replace the Carriage PCA • Replace the Main PCA
  • Code: 0200
  • Description: DRAM
    The read/write of the image band memory on the Main PCA was diagnosed and an error was detected
  • Remedy: • Replace the Main PCA
  • Code: 0400
  • Description: USB Register
    The read/write of the USB controller on the Main PCA was diagnosed and an error was detected.
  • Remedy: • Replace the Main PCA
  • Code: 0800
  • Description: Power Supply (+36V, +24V, +12V)
    The power supplies of +36, +24 and +12 V were diagnosed and could not be detected.
  • Remedy: • Open the Electronics Cover and check LED 11 and LED 13. • If both LED 11 and LED 13 are OFF, then try the following: – Check the Interlock Switches to make sure they are installed/connected correctly. Make sure that the Rear Cover lips (that activate the Interlock Switches) are not bent and that the Rear Cover is closed correctly. – If the Interlock Switches are installed and connected correctly, then replace the Main PCA • If both LED 11 and LED 13 are ON, then try the following: – Check whether the correct voltages are supplied from the power source (refer to the table below). If the correct voltages are not supplied, then replace the Power Supply Unit – It is possible that this error occurred because of a faulty Main PCA. Replace the Main PCA – Check whether the motors have been short-circuited by testing +24 V. If +24 V is not supplied then replace both Scan-Axis/Paper-Axis Motors. If error continues, replace the Main PCA
  • Code: 1110
  • Description: GA_ATG Block Clear Error
    The ATG band memory block erase does not end. This error is checked during Boot-Up sequence and printing.
  • Remedy: • Replace the Main PCA
  • Code: 1111
  • Description: GA_ATG DMA Transfer Error
    There is a problem in the data path. This error is checked during printing.
  • Remedy: • Make sure that the host PC and the Printer are connected correctly via a USB Cable. • Replace the Main PCA
  • Code: 112x
  • Description: Vacuum Fan Error x = 0: The Vacuum Fan (Wiping Side) has failed. x = 1: The Vacuum Fan (Center of the Platen) has failed. x = 2: The Vacuum Fan (Capping Side) has failed.
  • Remedy: • Make sure that the failing Vacuum Fan Cable is connected correctly and is not damaged • Replace the failing Vacuum Fan • If the error continues, replace the Add-On (HEB2) Control PCA (for errors where x = 0 or 1) and the Main PCA (for errors where x = 2, 3 or 4).
  • Code: 1140
  • Description: Flash ROM Write Error
    A time-out error occurs when the NVRAM contents are being saved in the flash memory in Maintenance Mode and erasing does not end.
  • Remedy: • Replace the Main PCA