Description: Curing module X PCA fan no spinning detected. Module disabled, substrate going under this module won't be cured. But, if module is required to print, run subsystem diagnostic. If problem persists, call support.
Causes: The fan is not detected to be spinning. The problem could be the fan itself, the fan power, or the tachometer signal.
Remedy: 1. Check the fan connections. 2. Replace the fan.
Description: Curing module X fan connector issue. Module disabled, substrate going under this module won't be cured. But, if module is required to print, run subsystem diagnostic. If problem persists, call support.
Causes: a. Fan failure b. PCA failure
Remedy: 1. Check the fan connection. 2. Replace the fan. 3. Replace the PCA.
Description: Curing module X safety relay failure detected. Safety mechanism disabled, printer can't be operated. Reboot in diagnostic mode and run safety diagnostics. If problem persists, call support.
Causes: Curing may be disabled by satety equipment.
Remedy: Run safety and e-cabinet diagnostics, and replace any faulty part.
Description: Capping station movement test fault. Reboot in diagnostic mode and run subsystem diagnostic. If problem persists, call support and store prinhead in the orange caps.
Causes: a. Shutter blocked b. Friction too high
Remedy: 1. Use a screwdriver to check that the shutter is not jammed against the structure. 2. Clean and grease worm and rod sliders. 3. Run the backlash/elasticity diagnostic. 4. If the problem persists, replace the part.
Description: Capping bump switch not activated. Reinitialize carriage. If problem persists, run subsystem diagnostic call support and store printhead in the orange caps.
Causes: End of movement switch fail
Remedy: 1. Run capping bump switch test, check that the shuttle is closing the switch, and check that the switch status is reported properly. 2. If the switch works well but the shutter doesn't manage to close it, check that friction is not too high. 3. Otherwise check the switch connection or replace the switch.
Description: Motor driver PCA comm failure. Reinitialize carriage. If problem persists, call support.
Causes: a. Cabling problem b. PCA failure
Remedy: 1. Check all cables arriving at the PCA and from PCA to capping and drop detection shutter motors and sensors. 2. Replace the remote controller board.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.