Description: Curing module X PCA error. Module disabled, substrate going under this module won't be cured. But if module is required to print, reinstall/upgrade printer firmware. If problem persists, call support.
Causes: a. Curing PCA internal error b. Curing PCA malfunction
Remedy: 1. Reinstall or update the printer’s firmware. 2. Replace the curing PCA.
Description: Curing module X comm error between curing PCA and e-box. Module disabled, substrate going under this module won't be cured. But, if module is required to print, run subsystem diagnostic. If problem persists, call support.
Causes: a. Curing PCA connection problem b. Curing PCA malfunction
Remedy: 1. Check connections. 2. Replace the curing PCA.
Description: Curing module X PCA DC supply error. Module disabled, substrate going under this module won't be cured. But, if module is required to print, run subsystem diagnostic. If problem persists, call support.
Causes: a. DC power error b. Curing PCA problem c. Cabling problem d. Curing PCA power supply error
Description: Curing module X PCA temp too high. Module disabled, substrate going under this module won't be cured. But, if module is required to print, run subsystem diagnostic. If problem persists, call support.
Causes: a. Ambient temperature too high b. Not enough airflow in module c. Failure in temperature control
Remedy: 1. Check the ambient temperature. 2. Check that the fans are working, and that the holes in the curing plate are not blocked. 3. Check the curing PCA.
Description: Curing module X temperature channel 1 out of range (recirculation). Module disabled, substrate going under this module won't be cured. But, if module is required to print, run subsystem diagnostic. If problem persists, call support.
Causes: a. Ambient temperature too high b. Not enough airflow in module c. Failure in temperature control
Remedy: 1. Check the ambient temperature. 2. Check that the fans are working, and that the holes in the curing plate are not blocked. 3. Check the curing PCA.
Description: Curing module X chamber 1 Temperature sensor failure Module disabled, substrate going under this module won't be cured. But if module is required to print, run subsystem diagnostic. If the problem persists, call support.
Causes: Temperature sensor problem
Remedy: Replace the temperature sensor.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.