Description: Curing module 0X overcurrent warning. contact your support representative to check input voltage configuration.
Causes: a. Wrong configuration of AC input tension b. AC input tension out of range c. Resistor degradation
Remedy: 1. Check AC input tension and reconfigure the printer’s AC input configuration. 2. Check resistor and replace if necessary.
Code: 16.02.01:01, 16.02.02:01
Description: Curing module X PCA error. Module disabled, substrate going under this module won't be cured. But if module is required to print, reinstall/upgrade printer firmware. If problem persists, call support.
Causes: a. Curing PCA internal error b. Curing PCA malfunction
Remedy: 1. Reinstall or update the printer’s firmware. 2. Replace the curing PCA.
Code: 16.02.01:04, 16.02.02:04
Description: Curing module X comm error between curing PCA and e-box. Module disabled, substrate going under this module won't be cured. But, if module is required to print, run subsystem diagnostic. If problem persists, call support.
Causes: a. Curing PCA connection problem b. Curing PCA malfunction
Remedy: 1. Check connections. 2. Replace the curing PCA.
Code: 16.02.01:10, 16.02.02:10
Description: Curing module X PCA DC supply error. Module disabled, substrate going under this module won't be cured. But, if module is required to print, run subsystem diagnostic. If problem persists, call support.
Causes: a. DC power error b. Curing PCA problem c. Cabling problem d. Curing PCA power supply error
Remedy: Replace any faulty part.
Code: 16.02.01:21, 16.02.02:21
Description: Curing module X PCA temp too high. Module disabled, substrate going under this module won't be cured. But, if module is required to print, run subsystem diagnostic. If problem persists, call support.
Causes: a. Ambient temperature too high b. Not enough airflow in module c. Failure in temperature control
Remedy: 1. Check the ambient temperature. 2. Check that the fans are working, and that the holes in the curing plate are not blocked. 3. Check the curing PCA.
Code: 16.03.00:03
Description: Curing bottom plate model not set or wrongly set in firmware. Contact your support representative.
Causes: Curing bottom plate model or revision is not properly set in the printer.
Remedy: Go to the diagnostic utilities in Print Care and run the set curing bottom plate diagnostic in order to set the right model and revision.
Code: 16.10.01:20 ... 16.10.06:20
Description: Curing module X temperature channel 1 out of range (recirculation). Module disabled, substrate going under this module won't be cured. But, if module is required to print, run subsystem diagnostic. If problem persists, call support.
Causes: a. Ambient temperature too high b. Not enough airflow in module c. Failure in temperature control
Remedy: 1. Check the ambient temperature. 2. Check that the fans are working, and that the holes in the curing plate are not blocked. 3. Check the curing PCA.
Code: 16.11.01:01 ... 16.11.06:01
Description: Curing module X chamber 1 Temperature sensor failure Module disabled, substrate going under this module won't be cured. But if module is required to print, run subsystem diagnostic. If the problem persists, call support.