Description: Curing module X chamber 1 fan no spinning detected. Module disabled, substrate going under this module won't be cured. But if module is required to print, run subsystem diagnostic. If the problem persists, call support.
Causes: The fan is not detected to be spinning. The problem could be the fan itself, the fan power, or the tachometer signal.
Remedy: 1. Check the fan connections. 2. Replace the fan.
Code: 16.14.01:15 ... 16.14.06:15
Description: Curing module X chamber 1 open circuit detected. Module disabled, substrate going under this module won't be cured. But, if module is required to print, run subsystem diagnostic. If problem persists, call support.
Causes: a. Curing PCA fuse blown b. Resistor failure c. Resistor cabling error d. Curing PCA failure (relay, triac, current sensor) e. Curing PCA firmware bug
Remedy: 1. Reinstall or update the firmware. 2. Check the curing PCA and replace it if necessary. See Curing and vapor removal PCA. 3. Check the resistor and replace it if necessary.
Code: 16.15.01:01 ... 16.15.06:01
Description: Curing module X resistor 1 failure. Module disabled, substrate going under this module won't be cured. But, if module is required to print, run subsystem diagnostic. If problem persists, call support.
Causes: a. Curing PCA firmware bug b. Curing PCA failure (relay or triac)
Remedy: 1. Reinstall or update the firmware. 2. Check the curing PCA and replace it if necessary.
Code: 16.20.01:20 ... 16.20.06:20
Description: Curing module X temperature channel 2 out of range (recirculation). Module disabled, substrate going under this module won't be cured. But, if module is required to print, run subsystem diagnostic. If problem persists, call support.
Causes: a. Ambient temperature too high b. Not enough airflow in module c. Failure in temperature control
Remedy: 1. Check the ambient temperature. 2. Check that the fans are working, and that the holes in the curing plate are not blocked. 3. Check the curing PCA.
Code: 16.21.01:01 ... 16.21.06:01
Description: Curing module X chamber 2 temperature sensor failure. Module disabled, substrate going under this module won't be cured. But, if module is required to print, run subsystem diagnostic. If problem persists, call support.
Causes: a. Ambient temperature too high b. Not enough airflow in module c. Failure in temperature control
Remedy: Replace temperature sensor.
Code: 16.23.01:01 ... 16.23.06:01
Description: Curing module X chamber 2 fan no spinning detected. Module disabled, substrate going under this module won't be cured. But, if module is required to print, run subsystem diagnostic. If problem persists, call support.
Causes: The fan is not detected to be spinning. The problem could be the fan itself, the fan power, or the tachometer signal.
Remedy: 1. Check the fan connections. 2. Replace the fan.
Code: 16.24.01:15 ... 16.24.06:15
Description: Curing module X chamber 2 open circuit detected. Module disabled, substrate going under this module won't be cured. But, if module is required to print, run subsystem diagnostic. If problem persists, call support.
Causes: a. Curing PCA fuse blown b. Resistor failure c. Resistor cabling error d. Curing PCA failure (relay, triac, current sensor) e. Curing PCA firmware bug
Remedy: 1. Reinstall or update the firmware. 2. Check the curing PCA and replace it if necessary. See Curing and vapor removal PCA. 3. Check the resistor and replace it if necessary.
Code: 16.25.01:01 ... 16.25.06:01
Description: Curing module X resistor 2 failure. Module disabled, substrate going under this module won't be cured. But, if module is required to print, run subsystem diagnostic. If problem persists, call support.
Causes: a. Curing PCA firmware bug b. Curing PCA failure (relay or triac)
Remedy: 1. Reinstall or update the firmware. 2. Check the curing PCA and replace it if necessary.