Description: CLC failure. Calibration wasn't completed successfully. Run subsystem diagnostics. If the problem persists, call your support representative.
Causes: a. SOL shutter is jammed. b. Sensor is dirty.
Remedy: Replace the sensor.
Code: 58.00.00:02
Description: CLC measures not increasing value. Check that you have set the right substrate. Run subsystem diagnostics. If the problem persists, call your support representative.
Causes: a. Job pattern is not printed correctly. b. Sensor shutter is jammed. c. Sensor has failed.
Remedy: 1. Check the job pattern. 2. Check printhead nozzle health. 3. Check the sensor shutter. 4. Replace the sensor.
Code: 58.00.00:75
Description: Error saving data on hard disk, out of memory. Calibration wasn't completed successfully. Run subsystem diagnostics. If the problem persists, call your support representative.
Causes: a. Temporary problem b. Permanent damage to the hard disk drive
Remedy: Run subsystem diagnostic.
Code: 58.00.00:85
Description: CLC white substrate measure out of range. Check that you have set the right substrate. Run subsystem diagnostics. If the problem persists, call your support representative.
Causes: If substrate and printed job are OK, the most probable cause is a sensor failure.
Remedy: Replace the SOL sensor.
Code: 58.02.00:02
Description: SOL shutter door open/close check failure. SOL sensor unusable due to shutter door issue. Run subsystem diagnostics. If the problem persists, call your support representative.
Causes: SOL sensor is open because of a substrate jam, or is failing.
Remedy: Run the SOL calibration diagnostic and open the cleaning roll door to check that the shutter is properly closed. If it is failing, replace it.
Code: 58.03.00:04
Description: Color sensor communication error. Run subsystem diagnostics. If the problem persists, call your support representative.
Causes: a. Cabling problem b. Color sensor problem
Remedy: 1. Check cabling, and replace it if necessary. 2. Run subsystem diagnostic. 3. Check the sensor, and replace it if necessary.
Code: 58.03.00:84
Description: SOL calibration failure. Calibration wasn't completed successfully. Run subsystem diagnostics. If the problem persists, call your support representative.
Causes: a. Calibration has failed. b. The printheads have a lot of blocked nozzles and the pattern is not printed properly. c. The sensor is faulty.
Remedy: 1. Check printhead health. 2. Repeat the calibration and replace the sensor if the problem persists. 3. Run subsystem diagnostic.
Code: 58.03.00:85
Description: SOL measure error (out of range measure). Calibration wasn't completed successfully. Run subsystem diagnostics. If the problem persists, call your support representative.
Causes: a. Calibration has failed. b. The printheads have a lot of blocked nozzles and the pattern is not printed properly. c. The sensor is faulty.
Remedy: 1. Run subsystem diagnostic. 2. Check printhead health. 3. Repeat the calibration and replace the sensor if the problem persists.