Description: CLC failure. Calibration wasn't completed successfully. Run subsystem diagnostics. If the problem persists, call your support representative.
Causes: a. SOL shutter is jammed. b. Sensor is dirty.
Description: CLC measures not increasing value. Check that you have set the right substrate. Run subsystem diagnostics. If the problem persists, call your support representative.
Causes: a. Job pattern is not printed correctly. b. Sensor shutter is jammed. c. Sensor has failed.
Remedy: 1. Check the job pattern. 2. Check printhead nozzle health. 3. Check the sensor shutter. 4. Replace the sensor.
Description: Error saving data on hard disk, out of memory. Calibration wasn't completed successfully. Run subsystem diagnostics. If the problem persists, call your support representative.
Causes: a. Temporary problem b. Permanent damage to the hard disk drive
Description: CLC white substrate measure out of range. Check that you have set the right substrate. Run subsystem diagnostics. If the problem persists, call your support representative.
Causes: If substrate and printed job are OK, the most probable cause is a sensor failure.
Description: SOL shutter door open/close check failure. SOL sensor unusable due to shutter door issue. Run subsystem diagnostics. If the problem persists, call your support representative.
Causes: SOL sensor is open because of a substrate jam, or is failing.
Remedy: Run the SOL calibration diagnostic and open the cleaning roll door to check that the shutter is properly closed. If it is failing, replace it.
Description: SOL calibration failure. Calibration wasn't completed successfully. Run subsystem diagnostics. If the problem persists, call your support representative.
Causes: a. Calibration has failed. b. The printheads have a lot of blocked nozzles and the pattern is not printed properly. c. The sensor is faulty.
Remedy: 1. Check printhead health. 2. Repeat the calibration and replace the sensor if the problem persists. 3. Run subsystem diagnostic.
Description: SOL measure error (out of range measure). Calibration wasn't completed successfully. Run subsystem diagnostics. If the problem persists, call your support representative.
Causes: a. Calibration has failed. b. The printheads have a lot of blocked nozzles and the pattern is not printed properly. c. The sensor is faulty.
Remedy: 1. Run subsystem diagnostic. 2. Check printhead health. 3. Repeat the calibration and replace the sensor if the problem persists.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.