  • Code: 10.04.13:15
  • Description: E-cabinet MI fuse blown. The MI Motor 42V fuse has blown (F10).
  • Causes: MI Motor 42V fuse blown (F10)
  • Remedy: 1. Run the subsystem diagnostic. 2. Shut down the machine (completely, main switch off). 3. Replace the fuse F10. 4. If the problem persists, call support.
  • Code: 10.04.14:15
  • Description: E-cabinet MA fuse blown. The MA Motor 42V fuse has blown.
  • Causes: MA Motor 42V fuse blown (F9)
  • Remedy: 1. Run the subsystem diagnostic. 2. Shut down the machine (completely, main switch off). 3. Replace the fuse F9. 4. If the problem persists, call support.
  • Code: 10.04.15:15
  • Description: E-cabinet 42V CARR fuse blown. The carriage 42V CARR fuse has blown.
  • Causes: Carriage 42V fuse blown (F8)
  • Remedy: 1. Run the subsystem diagnostic. 2. Shut down the machine (completely, main switch off). 3. Replace the fuse F8. 4. If the problem persists, call support.
  • Code: 10.04.21:15
  • Description: E-cabinet ISS fuse blown. The ISS 24V fuse has blown.
  • Causes: ISS 24V fuse blown (F19)
  • Remedy: 1. Run the subsystem diagnostic. 2. Shut down the machine (completely, main switch off). 3. Replace the fuse F19. 4. If the problem persists, call support.
  • Code: 10.04.22:15
  • Description: E-cabinet VAPOR fuse blown. The vapor removal 24V fuse has blown.
  • Causes: Vapor removal 24V fuse blown (F20)
  • Remedy: 1. Run the subsystem diagnostic. 2. Shut down the machine (completely, main switch off). 3. Replace the fuse F20. 4. If the problem persists, call support.
  • Code: 10.04.31:15
  • Description: E-cabinet PPS fuse blown. The PPS 32V fuse has blown.
  • Causes: PPS 32V fuse blown (F7)
  • Remedy: 1. Run the subsystem diagnostic. 2. Shut down the machine (completely, main switch off). 3. Replace the fuse F7. 4. If the problem persists, call support.
  • Code: 10.04.32:15
  • Description: E-cabinet WW fuse blown. The printhead cleaning system 32V fuse has blown.
  • Causes: Printhead cleaning system 32V fuse blown (F6)
  • Remedy: 1. Run the subsystem diagnostic. 2. Shut down the machine (completely, main switch off). 3. Replace the fuse F6. 4. If the problem persists, call support.
  • Code: 10.04.33:15
  • Description: E-cabinet SVS fuse blown. The SVS 32V fuse has blown.
  • Causes: SVS 32V fuse blown (F5)
  • Remedy: 1. Run the subsystem diagnostic. 2. Shut down the machine (completely, main switch off). 3. Replace the fuse F5. 4. If the problem persists, call support.