Description: E-cabinet ISS power output overload. Run subsystem diagnostic. If problem persists, call your support representative.. The ISS 24V switch is overloaded.
Causes: ISS 24V switch overload
Remedy: 1. Reboot the printer. 2. Run the subsystem diagnostic. 3. If the problem persists, most likely there is a problem in the ISS.
Code: 10.05.22:40
Description: E-cabinet VAPOR power output overload. Run subsystem diagnostic. If problem persists, call your support representative.. The vapor removal 24V switch is overloaded.
Causes: Vapor removal 24V switch overload
Remedy: 1. Reboot the printer. 2. Run the subsystem diagnostic. 3. If the problem persists, most likely there is a problem in the Vapor removal.
Code: 10.05.31:40
Description: E-cabinet PPS power output overload. Run subsystem diagnostic. If problem persists, call your support representative.. The PPS 32V switch is overloaded.
Causes: PPS 32V switch overload
Remedy: 1. Reboot the printer. 2. Run the subsystem diagnostic. 3. If the problem persists, most likely there is a problem in the PPS.
Code: 10.05.32:40
Description: E-cabinet WW power output overload. Run subsystem diagnostic. If problem persists, call your support representative.. The printhead cleaning system 32V switch is overloaded.
Causes: Printhead cleaning system 32V switch overload
Remedy: 1. Reboot the printer. 2. Run the subsystem diagnostic. 3. If the problem persists, most likely there is a problem in the printhead cleaning system.
Code: 10.05.33:40
Description: E-cabinet SVS power output overload. Run subsystem diagnostic. If problem persists, call your support representative.. The SVS 32V switch is overloaded.
Causes: SVS 32V switch overload
Remedy: 1. Reboot the printer. 2. Run the subsystem diagnostic. 3. If the problem persists, most likely there is a problem in the SVS.
Code: 10.05.34:40
Description: E-cabinet TUR power output overload. Run subsystem diagnostic. If problem persists, call your support representative.. The take-up reel PCA 32V switch is overloaded.
Causes: Take-up reel PCA 32V switch overload
Remedy: 1. Reboot the printer. 2. Run the subsystem diagnostic. 3. If the problem persists, most likely there is a problem in the TUR sensor system.
Code: 10.05.41:40
Description: E-cabinet 12V CARR power output overload. Run subsystem diagnostics. If problem persists, call your support representative. The carriage 12V switch is overloaded.
Causes: Carriage 12V switch overload
Remedy: 1. Reboot the printer. 2. Run the subsystem diagnostic. 3. If the problem persists, most likely there is a problem in the Carriage.
Code: 10.05.42:40
Description: E-cabinet PSU-4-2 power output overload. Run subsystem diagnostic. If problem persists, call your support representative.. Unused 12V switch is overloaded.
Causes: Unused 12V switch overload
Remedy: No corrective actions as output is not used.