Description: E-cabinet TUR fuse blown. The take-up reel PCA 32V fuse has blown.
Causes: TUR PCA 32V fuse blown (F4)
Remedy: 1. Run the subsystem diagnostic. 2. Shut down the machine (completely, main switch off). 3. Replace the fuse F4. 4. If the problem persists, call support.
Code: 10.04.35:15
Description: E-cabinet PSU-3-5 fuse blown. The unused 32V fuse has blown.
Causes: Unused 32V fuse blown (F3)
Remedy: 1. Run the subsystem diagnostic. 2. Shut down the machine (completely, main switch off). 3. Replace the fuse F3. 4. If the problem persists, call support.
Code: 10.04.35:40
Description: E-cabinet PSU-3-5 power output overload. Run subsystem diagnostic. If problem persists, call your support representative.. Unused 32V switch is overloaded.
Causes: Unused 32V switch overload
Remedy: No corrective actions as output is not used.
Code: 10.04.41:15
Description: E-cabinet 12V CARR fuse blown. The carriage 12V fuse has blown.
Causes: Carriage 12V fuse blown (F2)
Remedy: 1. Run the subsystem diagnostic. 2. Shut down the machine (completely, main switch off). 3. Replace the fuse F2. 4. If the problem persists, call support.
Code: 10.04.42:15
Description: E-cabinet PSU-4-2 fuse blown. The unused 12V fuse has blown.
Causes: Unused 12V fuse blown (F1)
Remedy: 1. Run the subsystem diagnostic. 2. Shut down the machine (completely, main switch off). 3. Replace the fuse F1. 4. If the problem persists, call support.
Code: 10.04.51:15
Description: E-cabinet SAX fuse blown. The SAX 42V fuse has blown.
Causes: SAX 42V fuse blown (F13)
Remedy: 1. Run the subsystem diagnostic. 2. Shut down the machine (completely, main switch off). 3. Replace the fuse F13. 4. If the problem persists, call support.
Code: 10.04.52:15
Description: E-cabinet PSU-5-2 fuse blown. The unused 42V fuse has blown.
Causes: Unused 42V fuse blown (F14)
Remedy: 1. Run the subsystem diagnostic. 2. Shut down the machine (completely, main switch off). 3. Replace the fuse F14. 4. If the problem persists, call support.
Code: 10.04.61:15
Description: E-cabinet CURING-1 fuse blown. The curing-1 24V fuse has blown.
Causes: Curing-1 24V fuse blown (F18)
Remedy: 1. Run the subsystem diagnostic. 2. Shut down the machine (completely, main switch off). 3. Replace the fuse F18. 4. If the problem persists, call support.