Các lỗi thường gặp

Code :
  • Code: 10.05.51:40
  • Description: E-cabinet SAX power output overload. Run subsystem diagnostic. If problem persists, call your support representative.. The SAX 42V switch is overloaded.
  • Causes: SAX 42V switch overload
  • Remedy: 1. Reboot the printer. 2. Run the subsystem diagnostic. 3. If the problem persists, most likely there is a problem in the SAX motor.
  • Code: 10.05.52:40
  • Description: E-cabinet PSU-5-2 power output overload. Run subsystem diagnostic. If problem persists, call your support representative.. Unused 42V switch is overloaded.
  • Causes: Unused 42V switch overload
  • Remedy: No corrective actions as output is not used.
  • Code: 10.05.62:40
  • Description: E-cabinet DS-2 power output overload. Run subsystem diagnostic. If problem persists, call your support representative.. The DS-2 24V switch is overloaded.
  • Causes: DS-2 24V switch overload
  • Remedy: 1. Reboot the printer. 2. Run the subsystem diagnostic. 3. If the problem persists, most likely there is a problem in the DS-2 AC converter.
  • Code: 10.05.72:40
  • Description: E-cabinet DS-1 power output overload. Run subsystem diagnostic. If problem persists, call your support representative.. The DS-1 24V switch is overloaded.
  • Causes: DS-1 24V switch overload
  • Remedy: 1. Reboot the printer. 2. Run the subsystem diagnostic. 3. If the problem persists, most likely there is a problem in the DS-1 AC converter.
  • Code: 10.06.09:40
  • Description: One or more emergency stops are pressed. Run subsystem diagnostic. If problem persists, call your support representative.
  • Causes:
  • Remedy: 1. Ensure that no emergency stops are pressed. 2. Run safety diagnostics to check the emergency stops. 3. Run e-cabinet diagnostics and check the e-box interconnect PCA LEDs.
  • Code: 10.07.07:40
  • Description: Interlock bypass activated. Run subsystem diagnostic. If problem persists, call your support representative.
  • Causes: Safety bypass in the e-cabinet enabled
  • Remedy: Disable the bypass to operate the printer in normal mode. For the customer to use the printer normally, the bypass must be disabled.
  • Code: 10.08.00:01
  • Description: E-cabinet fan not working. Fan rotation feedback signal not detected
  • Causes: Fan malfunction or not connected
  • Remedy: 1. Check the fan cabling. 2. Replace the fan if necessary. See E-cabinet fan. 3. If the problem persists, call support.
  • Code: 10.09.00:01
  • Description: Safety circuit powered by default. The PCA detects power in the safety circuit when there should be no power.
  • Causes: PCA malfunction
  • Remedy: 1. Replace the PCA. 2. If the problem persists, call support.
‹ First  < 11 12 13 14 15 16 17 >  Last ›
popup

Số lượng:

Tổng tiền:

Danh mục