Description: Printmech: 12V to Vapor Removal PCA open circuit
Causes: The 12V cable from Printmech to Vapor Removal PCA has a problem Printmech PCA is damaged.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Printmech to Vapor Removal PCA cable. 2. Check the Printmech PCA.
Code: 12.23:10
Description: Printmech: 24V to Vapor Removal PCA open circuit
Causes: The 24V cable from Printmech to Vapor Removal PCA has a problem Printmech PCA is damaged.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Printmech to Vapor Removal PCA cable. 2. Check the Printmech PCA.
Code: 12.24:10
Description: Printmech: 12V to ISS, DD, 42Vdc motor drivers, Top cover fans and PZ fans open circuit
Causes: The 12V cable from Printmech to ISS, Interconnect and PZ fans has a problem Printmech PCA is damaged.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Printmech to ISS, Interconnect, and PZ fans cables. 2. Check the Printmech PCA.
Code: 12.25:10
Description: Printmech: 42V to Carriage PCA open circuit
Causes: The 42V cable from Printmech to Carriage PCA has a problem Printmech PCA is damaged.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Printmech to Carriage PCA cable. 2. Check the Printmech PCA.
Code: 12.26:10
Description: Printmech: Hannibal1 24V open circuit. Check APS relief valve, SVS motor and Rack engage motor
Causes: The 24V cable from Printmech to Interconnect has a problem Printmech PCA is damaged.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the APS relief valve, SVS motor and Rack engage motor. 2. Check the Printmech PCA.
Code: 12.27:10
Description: Printmech: Hannibal2 24V open circuit. Check Spit-on roller motor and Primer motor
Causes: The 24V cable from Printmech to Interconnect has a problem Printmech PCA is damaged.
Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Spit-on roller motor and Primer motor. 2. Check the Printmech PCA.