Description: Color PC drum motor malfunction
• The color PC drum motor does not rotate evenly even after the lapse of a given period of time while it is being started.
• The motor lock signal remains HIGH for a given period of consecutive time while the color PC drum motor is being rotated.
Remedy: 1 Check the connector between M4-PRCB PJ5 for proper connection and correct as necessary. 2 Check the M4 connector for proper drive coupling and correct as necessary. 3 M4 operation check. 4 Change M4. 5 Change PRCB.
Description: Main motor malfunction
• The main motor does not rotate evenly even after the lapse of a given period of time while it is being started.
• The motor lock signal remains HIGH for a given period of consecutive time while the main motor is being rotated.
Remedy: 1 Check the connector between M2-PRCB PJ6 for proper connection and correct as necessary. 2 Check the M2 connector for proper drive coupling and correct as necessary. 3 M2 operation check. 4 Change M2. 5 Change PRCB.
Description: Developing motor malfunction
• The developing motor does not rotate evenly even after the lapse of a given period of time while it is being started.
• The motor lock signal remains HIGH for a given period of consecutive time while the developing motor is being rotated.
Remedy: 1 Check the connector between M1-PRCB PJ5 for proper connection and correct as necessary. 2 Check the M1 connector for proper drive coupling and correct as necessary. 3 M1 operation check. 4 Change M1. 5 Change PRCB.
Description: MFP board cooling fan motor malfunction
• The MFP board cooling fan motor does not rotate evenly even after the lapse of a given period of time while it is being started.
• The motor lock signal remains HIGH for a given period of consecutive time while the MFP board cooling fan motor is being rotated.
Remedy: 1 Check the connector between FM12-relay CN64-PRCB PJ14 for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM12 operation check. 4 Change FM12. 5 Change PRCB.
Description: Cooling fan motor malfunction
• The cooling fan motor does not rotate evenly even after the lapse of a given period of time while it is being started.
• The motor lock signal remains HIGH for a given period of consecutive time while the cooling fan motor is being rotated.
Remedy: 1 Check the connector between FM11-relay CN29-PRCB PJ14 for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM11 operation check. 4 Change FM11. 5 Change PRCB.
Description: DC power supply fan motor malfunction
• The DC power supply fan motor does not rotate evenly even after the lapse of a given period of time while it is being started.
• The motor lock signal remains HIGH for a given period of consecutive time while the DC power supply fan motor is being rotated.
Remedy: 1 Check the connector between FM10-relay CN43-PRCB PJ14 for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM10 operation check. 4 Change FM10. 5 Change PRCB.
Description: Tray 3 media feed motor malfunction
• The motor lock signal remains HIGH for a given period of consecutive time while the media feed motor is being rotated.
Remedy: 1 Check the connector between M1-PCCB PJ3 for proper connection and correct as necessary. 2 Check the connector between PCCB PJ1, PJ2-relay CN53, CN70-PRCB PJ7 for proper connection and correct as necessary. 3 Check the M1 connector for proper drive coupling and correct as necessary. 4 M1 operation check. 5 Change M1. 6 Change PCCB. 7 Change PRCB.
Description: Tray 4 media feed motor malfunction
• The motor lock signal remains HIGH for a given period of consecutive time while the media feed motor is being rotated.
Remedy: 1 Check the connector between M1-PCCB PJ3 for proper connection and correct as necessary. 2 Check the connector between PCCB PJ1, PJ2-relay CN53, CN70-PRCB PJ7 for proper connection and correct as necessary. 3 Check the M1 connector for proper drive coupling and correct as necessary. 4 M1 operation check. 5 Change M1. 6 Change PCCB. 7 Change PRCB.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.