Các lỗi thường gặp

Code :
  • Code: C-0109
  • Description: Abnormality of the PF exit conveyance motor (M3) power in the PF drive board (PFUDB) of the 2nd tandem PF-702. An error detection signal (blowout of ICP) of M3 is detected when M3 is turned ON.
  • Causes: PF exit conveyance motor (M3: PF-703) PF drive board (PFUDB: PF-703)
  • Remedy: 1 Check the connector connection and the wiring between PFUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality, and then replace PFUDB. PF-703: 8-L 3 Replace M3 and PFUDB at a time.
  • Code: C-0110
  • Description: Abnormality of the registration section motor power in the ADU drive board (ADUDB). The error detection signals (blowout of ICP) of the ADU conveyance motor /2 (M16), the registration motor (M17) and the loop motor (M18) are detected after the print is started.
  • Causes: ADU conveyance motor /2 (M16) Registration motor (M17) Loop motor (M18) ADU drive board /2 (ADUDB2)
  • Remedy: 1 Check the connector connection and the wiring between ADUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality, and then replace ADUDB2. 23-L, 24-L 3 Replace ADUDB2. - 4 Replace M16, M17, M18 and ADUDB2 at a time.
  • Code: C-0111
  • Description: Abnormality of the duplex section motor power in the ADU drive board (ADUDB). The error detection signals (blowout of ICP) of the ADU reverse motor (M12), the reverse/exit motor (M13), the ADU accelerate motor (M14) and the ADU conveyance motor /1 (M15) are detected after the print is started.
  • Causes: ADU reverse motor (M12) Reverse/exit motor (M13) ADU accelerate motor (M14) ADU conveyance motor /1 (M15) ADU drive board /1 (ADUDB1)
  • Remedy: 1 Check the connector connection and the wiring between ADUDB and the motor, and repair it if any abnormality. - 2 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality, and then replace ADUDB1. 21-L, 22-L 3 Replace ADUDB1. - 4 Replace M12, M13, M14, M15 and ADUDB1 at a time.
  • Code: C-0113
  • Description: Abnormality 1 of the SD/CL_24V power for the printer control board (PRCB) tray. At the start, the error detection signals of the PRCB tray solenoid/ clutch ICP blowout and 24V cut off are detected.
  • Causes: DC power supply /2 (DCPS /2) Printer control board (PRCB)
  • Remedy: 1 Check the connector connection and the wiring related to DC24V between PRCB and DCPS /2, and repair it if any abnormality. - 2 Replace DCPS /2. - 3 Replace PRCB.
  • Code: C-0114
  • Description: Abnormality 2 of the SD/CL_24V power for the printer control board (PRCB) tray. When the error detection signal of the PRCB tray solenoid/clutch ICP blowout is detected but no 24V cut off is detected at the start.
  • Causes: Paper feed clutch /1 (CL4) Separation clutch /1 (CL5) Paper feed clutch /2 (CL6) Separation clutch /2 (CL7) Pick-up solenoid /1 (SD3) Pick-up solenoid /2 (SD4) Printer control board (PRCB)
  • Remedy: 1 Check the connector connection and the wiring related to DC24V between PRCB and clutch/solenoid, and repair it if any abnormality. - 2 Check the drive and the coupling of the clutch and the solenoid, repair it if any abnormality, and then replace PRCB. 5-F, 8-F 3 Replace PRCB. - 4 Replace the clutch, the solenoid and PRCB at a time.
  • Code: C-0115
  • Description: Abnormality 1 of the SD/CL_24V power for the printer control board (PRCB) vertical conveyance. At the start, the error detection signals of the PRCB vertical conveyance solenoid/clutch ICP blowout and 24V cut off are detected.
  • Causes: DC power supply /2 (DCPS /2) Printer control board (PRCB)
  • Remedy: 1 Check the connector connection and the wiring related to DC24V between PRCB and DCPS /2, and repair it if any abnormality. - 2 Replace DCPS /2. - 3 Replace PRCB.
  • Code: C-0116
  • Description: Abnormality 2 of the SD/CL_24V power for the printer control board (PRCB) tray. When the error detection signal of the PRCB tray solenoid/clutch ICP blowout is detected but no 24V cut off is detected at the start.
  • Causes: Pre-registration clutch /1 (CL1) Vertical conveyance clutch (CL2) Pre-registration clutch /2 (CL3) Erase lamp (EL) Tray lock solenoid /1 (SD1) Tray lock solenoid /2 (SD2) Drum claw solenoid (SD10) Printer control board (PRCB)
  • Remedy: 1 Check the connector connection and the wiring related to DC24V between PRCB and clutch/solenoid/EL, and repair it if any abnormality. - 2 Check the drive and the coupling of the clutch, the solenoid and EL, repair/replace it if any abnormality, and then replace PRCB. 10-F, 5-M 3 Replace PRCB. - 4 Replace the clutch, the solenoid, EL and PRCB at a time.
  • Code: C-0118
  • Description: Abnormality of the power for the PF drive board (PFUDB) SD/CL of the PF-702/703. At the start, the error detection signal of the PFUDB solenoid/clutch ICP blowout is detected.
  • Causes: PF drive board (PFUDB: PF-702/703)
  • Remedy: 1 Check the connector connection and the wiring on PFUDB, and repair it if any abnormality. - 2 Check the drive and the coupling of the solenoid and the clutch connected to PFUDB, repair/replace it if any abnormality, and then replace PFUDB. - 3 Replace PFUDB. - 4 If the same error cord occurs even after replacing PFUDB, replace the connected solenoid, the clutch and PFUDB at a time.