Các lỗi thường gặp

Code :
  • Code: C-1206
  • Description: 1st tandem LS-505 stacker tray lower limit abnormality. The stacker tray lower limit switch (MS3) is ON when the stacker tray up down motor (M1) is in the down operation. 33-6
  • Causes: Stacker tray lower limit switch (MS3: LS-505) Stacker tray up down motor (M1: LS-505) LS control board (LSCB: LS-505)
  • Remedy: 1 Check the stacker tray up down section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between LSCB and motor/switch, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. LS-505: 5-A 4 Check the switch operation, and repair/replace it if any abnormality. LS-505: 7-A 5 Replace MS3. - 6 Replace M1. - 7 Replace LSCB.
  • Code: C-1211
  • Description: 2nd tandem PF-505 stacker tray up down motor (M1) drive abnormality. The stacker tray encoder sensor (PS2) does not turn ON within a specified period of time after M1 turns ON. Or, the initial operation or the stacker tray down operation is not completed within a specified period of time. 33-7
  • Causes: Stacker tray encoder sensor (PS2: LS-505) Stacker tray up down motor (M1: LS-505) LS control board (LSCB: LS-505)
  • Remedy: 1 Check the stacker tray up down section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between LSCB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. LS-505: 5-A 4 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. LS-505: 5-A 5 Replace PS2. - 6 Replace M1. - 7 Replace LSCB.
  • Code: C-1212
  • Description: 2nd tandem LS-505 shift unit motor (M5) drive abnormality. The shift unit home sensor (PS11) does not turn OFF within a specified period of time after M5 turns ON. Or, PS11 does not turn ON within a specified period of time. 33-7
  • Causes: Shift unit home sensor (PS11: LS-505) Shift unit motor (M5: LS-505) LS control board (LSCB: LS-505)
  • Remedy: 1 Check the shift unit section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between LSCB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. LS-505: 6-A 4 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. LS-505: 5-H 5 Replace PS11. - 6 Replace M5. - 7 Replace LSCB.
  • Code: C-1213
  • Description: 2nd tandem LS-505 alignment motor (M7) drive abnormality. The alignment plate home sensor (PS12) does not turn ON within a specified period of time after M7 turns ON. Or, PS12 does not turn ON within a specified period of time. 33-7
  • Causes: Alignment plate home sensor (PS12: LS-505) Alignment motor (M7: LS-505) LS control board (LSCB: LS-505)
  • Remedy: 1 Check the alignment section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between LSCB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. LS-505: 7-A 4 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. LS-505: 5-H 5 Replace PS12. - 6 Replace M7. - 7 Replace LSCB.
  • Code: C-1214
  • Description: 2nd tandem LS-505 grip conveyance motor (M4) drive abnormality. The grip conveyance home sensor (PS5) does not turn ON within a specified period of time after M4 turns ON. 33-7
  • Causes: Grip conveyance home sensor (PS5: LS-505) Grip conveyance motor (M4: LS-505) LS control board (LSCB: LS-505)
  • Remedy: 1 Check the grip conveyance section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between LSCB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. LS-505: 6-A 4 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. LS-505: 2-H 5 Replace PS5. - 6 Replace M4. - 7 Replace LSCB.
  • Code: C-1215
  • Description: 2nd tandem LS-505 stacker tray upper limit abnormality. The stacker tray upper limit switch (MS2) is ON when the stacker tray up down motor (M1) is in the up operation. 33-7
  • Causes: Stacker tray upper limit switch (MS2: LS-505) Stacker tray up down motor (M1: LS-505) LS control board (LSCB: LS-505)
  • Remedy: 1 Check the stacker tray up down section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between LSCB and motor/switch, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. LS-505: 5-A 4 Check the switch operation, and repair/replace it if any abnormality. LS-505: 7-A 5 Replace MS2. - 6 Replace M1. - 7 Replace LSCB.
  • Code: C-1216
  • Description: 2nd tandem LS-505 stacker tray lower limit abnormality. The stacker tray lower limit switch (MS3) is ON when the stacker tray up down motor (M1) is in the down operation. 33-7
  • Causes: Stacker tray lower limit switch (MS3: LS-505) Stacker tray up down motor (M1: LS-505) LS control board (LSCB: LS-505)
  • Remedy: 1 Check the stacker tray up down section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between LSCB and motor/switch, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. LS-505: 5-A 4 Check the switch operation, and repair/replace it if any abnormality. LS-505: 7-A 5 Replace MS3. - 6 Replace M1. - 7 Replace LSCB.
  • Code: C-1221
  • Description: 1st folding release motor (M14) drive abnormality. The 1st folding cam home sensor (PS55) does not turn ON within a specified period of time after M14 turns ON. 33-0
  • Causes: 1st folding cam home sensor (PS55: FD-503) 1st folding release motor (M14: FD-503) Folding drive board (FDB: FD-503)
  • Remedy: 1 Check the 1st folding section, and clean/repair it if any abnormality. - 2 Check the connector connection and the wiring between FDB and motor/sensor, and repair it if any abnormality. - 3 Check the I/O drive of the motor and the coupling of the gear, and repair/replace it if any abnormality. FD-503: 1-B 4 Check I/O and the operation of the sensor, and repair/replace it if any abnormality. FD-503: 2-B 5 Replace PS55. - 6 Replace M14. - 7 Replace FDB.