Description: Transfer roller leak error (positive electrode)
• The feedback voltage of the transfer roller has been more than the certain voltage for 200msec. (Open detecting condition)
• The feedback voltage of the transfer roller has been insufficient for 200msec. (Leak detecting condition)
This error doesn’t happen when the front door (the inter lock) opens.
Causes: • Defective harness connected to HVP
• Defective the MD
Description: Transfer roller leak error (negative electrode)
The feedback voltage of the transfer roller has been more than the certain voltage (more than 4.5V) for 200msec. This error doesn’t happen when the front door (the inter lock) opens.
Causes: • Defective the MD
• Defective harness connected to the HVP
Description: Separation high-voltage error
The maximum rate of PWM duty (50%) occurs ten times in series (20msec x 10) This error doesn’t happen when the front door (the inter lock) opens.
Causes: • Defective the MD, HVP Connection harness.
Description: Transfer electric plus current error
Detecting "0" (Abnormal) ten times in series (200ms) while monitoring "HVP: T +: Output error detection signal" every 20m seconds. (Reboot the machine to clear this SC)
Description: Isolation voltage error
Detecting "0" (Abnormal) ten times in series (200ms) while monitoring "HVP: D: Output error detection signal" every 20m seconds. (Reboot the machine to clear this SC)
Description: Toner bottle motor overcurrent
Detecting "Low" for more than 200msec while the motor on. Motor locked up due to overcurrent to the drive section.