Remedy: 1. Replace the controller board. 2. Turn the main switch off and on. 3. Update the firmware on the controller.
Code: 900
Description: Electric counter error Abnormal data in the counters.
Causes: • Defective NVRAM • Defective controller
Remedy: 1. Check the connection between the NVRAM and controller. 2. Replace the NVRAM. 3. Replace the controller board.
Code: 910...915
Description: External Controller Error
Causes: The external controller alerted the machine about an error.
Remedy: 1. Please refer to the instructions for the external controller (application).
Code: 919
Description: External Controller Error 6 While EAC (External Application Converter), the conversion module, was operating normally, the receipt of a power line interrupt signal from the FLUTE serial driver was detected, or BREAK signal from the other station was detected.
Causes: • Power outage at the EFI controller • EFI controller was rebooted • Connection to EFI controller loose
Remedy: 1. Turn the main power switch off and on.
Code: 920
Description: Printer application error An error is detected in the printer application program. -00 No response when starting up the PM -01 Timeout error during the PM operation -02 Working memory error -03 Cannot start-up the filtering process -04 Abnormal exit from the filtering process