Description: Air Detection Frequency Error The amount of air allowed in the print head tank exceeded the threshold from the start of checking cycle. If the machine remains idle, small amounts of air will leak slowly into one or more of the sub tanks. There are two thresholds: •X The first threshold sets the amount of leakage within a 10-day period. •X The second threshold sets the amount of leakage allowed greater than a 10-day period. SC282-11 D Head 1 SC282-12 D Head 2 SC282-13 D Head 3 SC282-14 D Head 4 SC282-15 D Multiple Heads
Causes: •X Cycle the machine off/on.
Remedy:
Code: SC283
Description: Ink End Detection Error The mechanical ink end sensor has failed, or one of the ink supply pumps has failed.
Causes: •X Cycle the machine off/on •X Ink end sensor defective •X Replace ink supply unit
Remedy:
Code: SC285
Description: DRESS Sensor Calibration Error The reflected beams was measured less than 400 when the head gap was adjusted automatically.
Description: OCFS Ink Pump Reverse Suction Error The OCFS could not detect when the supply pump motor reversed because a feeler was broken or out of position, or an ink supply pump could not siphon ink. SC290-01 D Head 1 SC290-02 D Head 2 SC290-03 D Head 3 SC290-04 D Head 4 SC290-05 D Head 5
Causes: •X Cycle the machine off/on •X Replace print head (with new OCFS) •X Replace ink supply unit
Remedy:
Code: SC293-01 ... SC293-05
Description: OCFS Ink Timeout During Filling The OCFS feeler is out of position and cannot be read, or one of the ink supply pumps is not pumping ink. SC293-01 D Head 1 SC293-02 D Head 2 SC293-03 D Head 3 SC293-04 D Head 4 SC293-05 D Head 5
Causes: •X Replace the ink supply unit •X Replace ink end sensor
Remedy:
Code: SC400
Description: DRESS Sensor Calibration Error The automatic head gap adjustment (gap between print heads) failed.
Description: Paper Feed Pressure Release Operation Error: Roll 1 Within 3 sec. after the release and application of pressure in Roll Unit 1, there was no signal from the paper release sensor.