Description: Machine Type Information Error
After the machine is powered on, a mismatch is detected between the CPM information sent from the controller to the engine.
Causes: • Replace the controller board with the correct board.
Code: 997
Description: Software Error 4: Cannot select application function
An application does not start after the user pushed the correct key on the operation panel.
Causes: • Software bug • A RAM or DIMM option necessary for the application is not installed or not installed correctly.
Code: 998
Description: Software Error 5: Application cannot start
Register processing does not operate for an application within 60 s after the machine power is turned on. No applications start correctly, and all end abnormally.
Causes: • Software bug • A RAM or DIMM option necessary for the application is not installed or not installed correctly.
Code: 999
Description: Program download error
The download (program, print data, language data) from the IC card does not execute normally.
Causes: • Board installed incorrectly • BICU defective • IC card defective • NVRAM defective • Loss of power during downloading Primarily intended for operating in the download mode, logging is not performed with SC999.