Description: Communication timeout error between BICU and paper tray unit
The BICU cannot receive a response within 100 ms after 3 attempts after sending data to the paper tray unit.
Causes: • Serial line connecting BICU and paper tray unit unstable • External noise • BICU board and paper tray main board connection defective or loose • Paper tray main board defective • BICU board defective
Code: 624
Description: Communication break error between BICU and paper tray unit
The BICU cannot communicate with the paper tray unit due to receiving a break signal.
Causes: • Serial line connecting BICU and paper tray unit unstable • External noise • BICU board and paper tray unit connection defective • Optional paper tray unit interface board defective • BICU board defective
Code: 626
Description: Communication timeout error between BICU and LCT
The BICU cannot receive a response within 100 ms after 3 attempts after attempting to communicate with the LCT.
Causes: • Serial line connecting BICU and LCT unit unstable • External noise • BICU board and LCT main board connection defective or loose • LCT interface board defective • BICU board defective
Code: 627
Description: Communication break error between BICU and LCT
The BICU cannot communicate with the LCT unit due to receiving a break signal.
Causes: • Serial line connecting BICU and LCT unit unstable • External noise • BICU board and LCT main board connection defective or loose • LCT interface board defective • BICU board defective
Code: 670
Description: Engine startup error
The BICU failed to respond with the prescribed time when the machine was turned on.
Causes: • Connections between BICU and controller board are loose, disconnected, or damaged • Replace the BICU • Replace the controller board
Code: 672
Description: Controller startup error
• After power on, the line between the controller and the operation panel did not open for normal operation. • After normal startup, communication with the controller stopped.
Description: GAVD block 12C bus error
The I2C bus of the BICU is defective
Causes: • Replace BICU
Code: 722
Description: Finisher jogger motor error
The finisher jogger HP sensor did not return to the home position, or move out of the home position, within 1.25 sec. Staple mode cannot be used.