Description: Fusing overheat error (hardware circuit detection)
The dual monitoring circuitry of the BICU detected temperature above 250oC (482oF) and tripped the relay circuit off.
Causes: • Check harnesses and connectors of PSU, IOB, BICU • PSU defective • IOB defective • BICU defective • Fusing thermistor defective or wrong type
Description: Fusing lamp remains on
After warm-up the fusing lamp remained at full power for 10 sec. (center) and 15 sec. (ends) without the hot roller rotating.
Causes: • One or both thermistors out of position.
Description: Zero cross signal error
One of the following occurred: 1. The fusing relay remained off for 50 ms after power on and continued to remain off after the after 3 attempts to detect the zero-cross signal. 2. During 11 zero-cross signal detections, two zero-cross signal detections were below 44 Hz. 3. The zero-cross signal could not be detected within 3 sec. after the fusing relay switched on.
Causes: • PSU defective • Noise on the ac power line
Description: Fusing unit jam
The fusing exit sensor detected a fusing unit paper late jam three times. The paper was late and the fusing exit sensor could not detect the paper three times.
Causes: • Remove the paper that is stopped in the fusing unit. • Check that the fusing unit is clean and has no obstacles in the paper feed path. • If the error persists, replace the fusing unit
Description: Communication timeout error between BICU and finisher
The BICU did receive a response within 100 ms after 3 attempts after sending data to the finisher.
Causes: • Serial line connecting BICU and finisher unstable • External noise • BICU board and finisher main board connection defective or loose • Finisher main board defective • BICU board defective
Description: Communication timeout error between BICU and finisher
A break (low) signal was received from the finisher.
Causes: • Serial line connecting BICU and finisher unstable • External noise • BICU board and finisher main board connection defective or loose • Finisher main board defective • BICU board defective
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.