Code :
  • Code: 551-00
  • Description: Broken fusing (End) thermistor wire
    At least ten times, the temperature is detected to stay at 0 deg C or less for three seconds.
  • Causes: - Broken thermistor wire - Bad connector contact
  • Remedy: • Clear the SP: fusing SC. • Check the connector connection. • Replace the fusing (End) thermistor.
  • Code: 552-02
  • Description: Fusing (End) thermistor not reloaded 1
    The heating (End) thermistor does not reach 80 deg C 7.7 seconds after the start of heat control (during normal startup control)
  • Causes: • Stained thermopile lens • Deformed or floating thermistor • Input voltage out of range • The overtemperature prevention mechanism started working
  • Remedy: • Clear the SP: fusing SC. • Replace the Fusing Unit.
  • Code: 552-03
  • Description: Fusing (End) thermistor not reloaded 2
    The heating (End) thermistor does not reach 80 deg C 7.7 seconds after the start of heat control (during normal startup control)
  • Causes: • Stained thermopile lens • Deformed or floating thermistor • Input voltage out of range • The overtemperature prevention mechanism started working
  • Remedy: • Clear the SP: fusing SC. • Replace the Fusing Unit.
  • Code: 552-04
  • Description: Fusing (End) thermistor not reloaded 3
    The heating (End) thermistor does not reach 80 deg C 7.7 seconds after the start of heat control (during normal startup control)
  • Causes: • Stained thermopile lens • Deformed or floating thermistor • Input voltage out of range • The overtemperature prevention mechanism started working
  • Remedy: • Clear the SP: fusing SC. • Replace the Fusing Unit.
  • Code: 553-00
  • Description: Fusing (End) thermistor high-temperature detected (software)
    The temperature is detected to stay at 230 deg C or higher for one second.
  • Causes: • Shorted triac • Failed Engine Board
  • Remedy: • Clear the SP: fusing SC. • Replace the PSU. • Replace the Engine Board.
  • Code: 554-00
  • Description: Fusing (End) thermistor high-temperature detected (software)
    The hardware high-temperature error Sensor flag is detected at 10 ms intervals.
  • Causes: • Damaged triac (shorted) • Failed engine control board • Failed fusing thermopile • Failed fusing thermistor • Abnormal fusing control software behavior • The PWM signal is continuously supplied from the IH inverter (due to a software or temperature Sensor error).
  • Remedy: • Clear the SP: fusing SC. • Replace the PSU. • Replace the Engine Board. • Replace the fusing thermopile. • Replace the Fusing Unit.
  • Code: 555-00
  • Description: Fusing (End) heater stay ON
    The fusing (End) heater stays ON for 8.6 seconds or more when in stand-by state (or the fusing roller is not rotating).
  • Causes: • Deformed or floating thermistor • Broken fusing lamp wire • The overtemperature prevention mechanism started working
  • Remedy: • CLEAR THE SP: FUSING SC. • Replace the thermistor. • Replace the fusing (End) lamp.
  • Code: 557-00
  • Description: Zero-crossing frequency exceeded
    The number of zero-crossing interrupts exceeds a certain value in 500 ms.
  • Causes: The frequency of the commercial power supply line is unstable or noise occurs
  • Remedy: