Các lỗi thường gặp

Code :
  • Code: 559-00
  • Description: Fusing jam detected 3 times in succession
    Fusing jam is detected three times in succession.
  • Causes: Paper is wrapped around the fusing roller.
  • Remedy: CLEAR THE SP: FUSING SC.
  • Code: 561-00
  • Description: Broken pressure (Center) thermistor wire
    At least ten times, the temperature is detected to stay at 0 deg C or less for three seconds.
  • Causes: - Broken thermistor wire - Bad connector contact
  • Remedy: • CLEAR THE SP: FUSING SC. • Check the connector connection. • Replace the fusing (End) thermistor.
  • Code: 562-00
  • Description: Pressure (Center) thermistor not reloaded
    The pressure (Center) thermistor does not reach 40 deg C 17.8 seconds after the start of heat control (during normal startup control).
  • Causes: • Stained thermopile lens • Deformed or floating thermistor • Input voltage out of range • The overtemperature prevention mechanism started working
  • Remedy: • CLEAR THE SP: FUSING SC. • Replace the Fusing Unit.
  • Code: 563-00
  • Description: Pressure (Center) thermistor high-temperature detected (software)
    The temperature is detected to stay at 230 deg C or higher for one second.
  • Causes: • Shorted triac • Failed Engine Board
  • Remedy: • CLEAR THE SP: FUSING SC. • Replace the PSU. • Replace the Engine Board.
  • Code: 564-00
  • Description: Pressure (Center) thermistor high-temperature detected (hardware)
    The pressure (Center) thermopile temperature becomes 250 or higher. (The hardware high-temperature error Sensor flag is detected at 10 ms intervals.)
  • Causes: • Damaged triac (shorted) • Failed Engine Board • Failed fusing thermopile • Failed fusing thermistor • Abnormal fusing control software behavior • The PWM signal is continuously supplied from the IH inverter (due to a software or temperature Sensor error).
  • Remedy: • CLEAR THE SP: FUSING SC. • Replace the PSU. • Replace the Engine Board. • Replace the fusing thermopile. • Replace the Fusing Unit.
  • Code: 571-00
  • Description: Broken pressure (End) thermistor wire At least ten times, the temperature is detected to stay at 0 deg C or less for three seconds.
  • Causes: - Broken thermistor wire - Bad connector contact
  • Remedy: • CLEAR THE SP: FUSING SC. • Check the connector connection. • Replace the fusing (End) thermistor.
  • Code: 573-00
  • Description: Pressure (Center) thermistor high-temperature detected (software)
    The temperature is detected to stay at 230 deg C or higher for one second.e seconds
  • Causes: • Shorted triac • Failed Engine Board
  • Remedy: • CLEAR THE SP: FUSING SC. • Replace the PSU. • Replace the Engine Board.
  • Code: 574-00
  • Description: Pressure (End) thermistor high
    The pressure (Center) thermopile temperature becomes 250 deg C or higher. (The hardware high)
  • Causes: • Damaged triac (shorted) • Failed Engine Board • Failed fusing thermopile • Failed fusing thermistor • Abnormal fusing control software behavior • The PWM signal is continuously supplied from the IH inverter (due to a software or temperature Sensor error).
  • Remedy: • Clear the SP: fusing SC. • Replace the PSU. • Replace the Engine Board. • Replace the fusing thermopile. • Replace the Fusing Unit.