Description: Fusing lamp (Center) thermopile not reloaded 2 The heater (Center) thermistor does not reach the reload temperature 44 seconds after the start of motor rotation.
Causes: • Stained thermopile lens • Deformed or floating thermistor • Input voltage out of range • The overtemperature prevention mechanism started working
Remedy: • Clear the SP: fusing SC. • Clean the thermopile lens. • Replace the thermopile.
Code: 542-04
Description: Fusing lamp (Center) thermopile not reloaded 3 The heater (Center) thermistor does not reach 100 deg C 5.5 seconds after the start of heat control (during low-temperature start up control).
Causes: • Stained thermopile lens • Deformed or floating thermistor • Input voltage out of range • The overtemperature prevention mechanism started working
Remedy: • Clear the SP: fusing SC. • Clean the thermopile lens. • Replace the thermopile.
Code: 543-00
Description: Fusing (Center) thermopile high-temperature detected (software) The temperature is detected to stay at 230 deg C or higher for one second.
Causes: • Shorted triac • Failed Engine Board
Remedy: • Clear the SP: fusing SC. • Replace the PSU. • Replace the Engine Board.
Code: 544-00
Description: Fusing (Center) thermopile high-temperature detected (hardware) The hardware high-temperature error Sensor flag is detected at 10 ms intervals.
Causes: • Damaged triac (shorted) • Failed engine control board • Failed fusing thermopile • Failed fusing thermistor • Abnormal fusing control software behavior • The PWM signal is continuously supplied from the IH inverter (due to a software or temperature Sensor error).
Remedy: • Clear the SP: fusing SC. • Replace the PSU. • Replace the Engine Board. • Replace the fusing thermopile. • Replace the Fusing Unit.
Code: 545-00
Description: Fusing (Center) heater stay ON The fusing (Center) heater stays ON for 5.7 seconds or more when in stand-by state (or the fusing roller is not rotating).
Causes: • Deformed or floating thermistor • Broken fusing lamp wire • The overtemperature prevention mechanism started working
Remedy: • Clear the SP: fusing SC. • Clean the thermopile lens. • Replace the fusing thermopile. • Replace the fusing (Center) lamp.
Code: 547-01
Description: Zero-crossing error (adhered relay contact) When the fusing relay is in an OFF state, a "zero-crossing interrupt request" occurs in 50 ms.
Causes: Damaged fusing relay (adhered contact)
Remedy: • Turn the main power OFF and then ON. • Replace the harness. • Replace the PC board. • Replace the PSU.
Code: 547-02
Description: Zero-crossing error (bad relay contact) If a "zero-crossing interrupt request" does not occur when the fusing relay is in an ON state, an error results.
Remedy: • Turn the main power OFF and then ON. • Replace the harness. • Replace the Engine Board. • Replace the PSU. • Replace the fuse.
Code: 547-03
Description: Zero-crossing error (low frequency error) The number of zero-crossing interrupts does not reach a certain value in 500 ms.
Causes: The frequency of the commercial power supply line is unstable.
Remedy: • Turn the main power OFF and then ON. • Check the commercial power supply line. • Replace the harness. • Replace the Engine Board. • Replace the PSU.