Các lỗi thường gặp

Code :
  • Code: 542-03
  • Description: Fusing lamp (Center) thermopile not reloaded 2
    The heater (Center) thermistor does not reach the reload temperature 44 seconds after the start of motor rotation.
  • Causes: • Stained thermopile lens • Deformed or floating thermistor • Input voltage out of range • The overtemperature prevention mechanism started working
  • Remedy: • Clear the SP: fusing SC. • Clean the thermopile lens. • Replace the thermopile.
  • Code: 542-04
  • Description: Fusing lamp (Center) thermopile not reloaded 3
    The heater (Center) thermistor does not reach 100 deg C 5.5 seconds after the start of heat control (during low-temperature start up control).
  • Causes: • Stained thermopile lens • Deformed or floating thermistor • Input voltage out of range • The overtemperature prevention mechanism started working
  • Remedy: • Clear the SP: fusing SC. • Clean the thermopile lens. • Replace the thermopile.
  • Code: 543-00
  • Description: Fusing (Center) thermopile high-temperature detected (software)
    The temperature is detected to stay at 230 deg C or higher for one second.
  • Causes: • Shorted triac • Failed Engine Board
  • Remedy: • Clear the SP: fusing SC. • Replace the PSU. • Replace the Engine Board.
  • Code: 544-00
  • Description: Fusing (Center) thermopile high-temperature detected (hardware)
    The hardware high-temperature error Sensor flag is detected at 10 ms intervals.
  • Causes: • Damaged triac (shorted) • Failed engine control board • Failed fusing thermopile • Failed fusing thermistor • Abnormal fusing control software behavior • The PWM signal is continuously supplied from the IH inverter (due to a software or temperature Sensor error).
  • Remedy: • Clear the SP: fusing SC. • Replace the PSU. • Replace the Engine Board. • Replace the fusing thermopile. • Replace the Fusing Unit.
  • Code: 545-00
  • Description: Fusing (Center) heater stay ON
    The fusing (Center) heater stays ON for 5.7 seconds or more when in stand-by state (or the fusing roller is not rotating).
  • Causes: • Deformed or floating thermistor • Broken fusing lamp wire • The overtemperature prevention mechanism started working
  • Remedy: • Clear the SP: fusing SC. • Clean the thermopile lens. • Replace the fusing thermopile. • Replace the fusing (Center) lamp.
  • Code: 547-01
  • Description: Zero-crossing error (adhered relay contact)
    When the fusing relay is in an OFF state, a "zero-crossing interrupt request" occurs in 50 ms.
  • Causes: Damaged fusing relay (adhered contact)
  • Remedy: • Turn the main power OFF and then ON. • Replace the harness. • Replace the PC board. • Replace the PSU.
  • Code: 547-02
  • Description: Zero-crossing error (bad relay contact)
    If a "zero-crossing interrupt request" does not occur when the fusing relay is in an ON state, an error results.
  • Causes: - Damaged fusing relay (open contact) - Failed fusing relay drive circuit - PSU fuse (24VS) blown
  • Remedy: • Turn the main power OFF and then ON. • Replace the harness. • Replace the Engine Board. • Replace the PSU. • Replace the fuse.
  • Code: 547-03
  • Description: Zero-crossing error (low frequency error)
    The number of zero-crossing interrupts does not reach a certain value in 500 ms.
  • Causes: The frequency of the commercial power supply line is unstable.
  • Remedy: • Turn the main power OFF and then ON. • Check the commercial power supply line. • Replace the harness. • Replace the Engine Board. • Replace the PSU.