Description: DADF Pre Regi Sensor/DADF Regi Sensor/DADF Invert Sensor Static Jam Paper was detected by the applicable sensor at Power ON, Feeder Cover Interlock Close, or DADF Open Sensor Close
Remedy: 1. Check the applicable sensor for remaining paper, the Actuator for return failure, contamination on sensor, and etc. 2. Check the applicable sensor for operation failure. • DADF Pre Regi Sensor (Input Check[005-206]) (PL 56.14) • DADF Regi Sensor (Input Check[005-110]) (PL 56.14) • DADF Invert Sensor (Input Check[005-211]) (PL 56.10) 3. If no problem is found, replace the DADF PWB. (PL 56.2)
Code: 005-940
Description: DADF No Original Fail It was detected that the document was pulled out during document feed.
Remedy: Reload the document
Code: 005-948
Description: SS-Size Mismatch Jam on No Mix-size In No Mix mode, it was detected that a document with a shorter size in Slow Scan (SS) direction was transported from the DADF
Remedy: 1. Check the size of the document that was fed by the User. 2. If the error is not cleared, check the following: • The DADF Pre Regi Sensor (Input Check [005-206]) for operation failure. (PL 56.14) • The Document Tray Size Sensor 1/2 (Input Check [005-221/222]) for operation failure. (PL 56.11) 3. If no problem is found, replace the DADF PWB. (PL 56.2)
Code: 007-270
Description: Tray 1 Paper Size Switch Broken The Tray 1 Size Sensor open circuit was detected. (The AD value is at its largest.) NOTE: If this is already detected, it will be displayed on the UI Panel when a Job is being performed.
Remedy: Check the following: • The connection between the Tray 1 Paper Size Switch J109 and the ESS/MCU PWB J414 for open circuit, short circuit, and poor contact. • Tray 1 Paper Size Switch: Analog Monitor [072-050]/Input Check [072-114] (PL 9.1) • The Tray 1 paper guide mechanism for damage and foreign substances. • The Tray 1 Paper Size Switch for damage, improper installation, and Actuator operation failure. If no problems are found, replace the ESS/MCU PWB (PL 18.3).
Code: 007-272
Description: Tray 3 Paper Size Switch Broken The Tray 3 Size Sensor open circuit was detected. (The AD value is at its largest.) NOTE: If this is already detected, it will be displayed on the UI Panel when a Job is being performed
Remedy: Check the following: • The connection between the Tray 3 Paper Size Switch J820 and the 2TM PWB J548 for open circuit, short circuit, and poor contact. • Tray 3 Paper Size Switch: Analog Monitor [072-052]/Input Check [072-110] (PL 11.1) • The Tray 3 paper guide mechanism for damage and foreign substances. • The Tray 3 Paper Size Switch for damage, improper installation, and Actuator operation failure. If no problems are found, replace the 2TM PWB (PL 11.6).
Code: 007-273
Description: Tray 4 Paper Size Switch Broken The Tray 4 Size Sensor open circuit was detected. (The AD value is at its largest.) NOTE: If this is already detected, it will be displayed on the UI Panel when a Job is being performed.
Remedy: Check the following: • The connection between the Tray 4 Paper Size Switch J824 and the 2TM PWB J548 for open circuit, short circuit, and poor contact. • Tray 4 Paper Size Switch: Analog Monitor [072-053]/Input Check [072-113] (PL 11.1) • The Tray 4 paper guide mechanism for damage and foreign substances. • The Tray 4 Paper Size Switch for damage, improper installation, and Actuator operation failure. If no problems are found, replace the 2TM PWB (PL 11.6).
Code: 010-311
Description: Fusing Unit Center Thermistor Defect An open circuit abnormality (the AD value of the STS is equivalent to the open circuit value) of the Heat Roll Center Thermistor was detected.
Remedy: Turn OFF the power and disconnect the Heat Roll Center Thermistor connector P/J600. Measure the resistance between the Heat Roll Center Thermistor J600 pin-1 and J600 pin-2. Is the resistance infinite? Y↓N→Reconnect the connector P/J600 and measure the resistance between the ESS/MCU PWB J403 pin-1 and J403 pin-2. Is the resistance infinite? Y↓N→Replace the ESS/MCU PWB (PL 18.3). Check the following connections for open circuits and poor contacts. • Between ESS/MCU PWB J403-1 and Heat Roll Center Thermistor P600-4 • Between ESS/MCU PWB J403-2 and Heat Roll Center Thermistor P600-3 Replace the Fusing Unit. (PL 7.1)
Code: 010-312
Description: Fusing Unit Rear Thermistor Defect An open circuit abnormality (the AD value of the STS is equivalent to the open circuit value) of the Heat Roll Rear Thermistor was detected.
Remedy: Turn OFF the power and disconnect the Heat Roll Rear Thermistor connector P/J600. Measure the resistance between the Heat Roll Rear Thermistor J600 pin-3 and J600 pin-4. Is the resistance infinite? Y↓N→Reconnect the connector P/J600 and measure the resistance between the ESS/MCU PWB J403 pin-3 and J403 pin-4. Is the resistance infinite? Y↓N→Replace the ESS/MCU PWB (PL 18.3). Check the following connections for open circuits and poor contacts. • Between ESS/MCU PWB J403-3 and Heat Roll Rear Thermistor P600-2 • Between ESS/MCU PWB J403-4 and Heat Roll Rear Thermistor P600-1 Replace the Fusing Unit. (PL 7.1)