Causes: Main PCA to PrintMech Blue 2 cable does not seem to be connected
Remedy: • Check that the Main PCA to PrintMech Blue 2 cable is not damaged. • Check that the Main PCA to PrintMech Blue 2 cable is correctly connected to the Main PCA and the PrintMech PCA. • Replace the Main PCA to PrintMech Blue 2 cable (which is included in the Electronics Module Cable Kit).
Remedy: • Turn the power off at the rear of the printer and disconnect the power cord. Reconnect the power cord and turn on the printer. • Make sure that the Service Station path is clear. Remove any visible obstacles (such as foam from the printerfs packaging, screws and plastic parts) restricting the movement of the Service Station. • If the System Error continues, replace the Service Station
Remedy: • Turn the power off at the rear of the printer and disconnect the power cord. Reconnect the power cord and turn on the printer. • Make sure that the Service Station path is clear. Remove any visible obstacles (such as foam from the printerfs packaging, screws and plastic parts) restricting the movement of the Service Station. • If the System Error continues, replace the Service Station
Causes: Air Pressurization System failure; unable to pressurize or depressurize tubes
Remedy: • Turn the power off at the rear of the printer and disconnect the power cord. Reconnect the power cord and turn on the printer. • Check that the APS cable is not damaged and is correctly connected to the PrintMech PCA. • Check that the air tubes are properly connected and are not kinked or pinched. • Replace the APS Assembly
Causes: ISS Top to ISS Bottom cable does not seem to be connected
Remedy: • Check that the ISS Top to ISS Bottom cable cable is not damaged. • Check that the ISS Top to ISS Bottom cable is correctly connected to the ISS Top PCA and ISS Bottom PCA. • Replace the ISS Top to ISS Bottom cable (which is included in the Electronics Module Cable Kit).
Remedy: • Turn the power off at the rear of the printer and disconnect the power cord. Reconnect the power cord and turn on the printer. • Ensure that the dummy printheads are correctly installed and purge the Ink Supply Tubes again. • If the problem persists, replace the Setup Printhead Kit.
Causes: A broken bag has been detected in one of the Ink Cartridges
Remedy: • Press Down + Cancel to see which cartridges have a broken bag. Remove the affected cartridges, shake each one three times within 2 seconds through a distance of about 40 cm, and check whether the cartridge air tower is contaminated with ink. If at least one cartridge is contaminated, replace the Ink Supply Tubes and Trailing Cable Ink Supply Tubes and Trailing Cable. NOTE: If the Ink Supply Tubes are to be replaced, the Ink Cartridges need to be checked beforehand to see if they are capable of purging the new tubes. If they are not, new Ink Cartridges must also be sent with the parts to be replaced. To check the Ink Cartridges, see Check ink supplies. • If no cartridge seems contaminated, follow the broken bag recovery procedure for more information
Causes: PrintMech to ISS Top cable does not seem to be connected
Remedy: • Check that the PrintMech to ISS Top cable cable is not damaged. • Check that the PrintMech to ISS Top cable is correctly connected to the PrintMech PCA and ISS Top PCA. • Replace the PrintMech to ISS Top cable (which is included in the Electronics Module Cable Kit).
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.