Các lỗi thường gặp

Code :
  • Code: 15.01.01:05, 15.01.02:05
  • Description: Drying PCA 0X scan axis timeout expired. Reinitialize carriage to recover the system. If this doesn't work, run subsystem diagnostics, and if problem is confirmed call your support representative. The scan axis has been stopped with lamps on for a longer time than the safety threshold set by the firmware.
  • Causes: a. Problems with scan-axis control b. Problems with drying hardware or cabling c. Intermittent DS1 or DS2 behavior or cabling problem d. AC line power-quality problems
  • Remedy: 1. Reinitialize the carriage, run the scan-axis friction test, and oil the carriage if necessary. 2. Run scan-axis diagnostics and check the encoder strip. 3. Check drying cables. Run drying subsystem diagnostics. Check the encoder cable to the drying PCA and replace failing parts. 4. Check DS-X cabling. Run e-cabinet diagnostics, and replace a failing power supply if necessary. 5. Ask the customer’s power utility provider about recent changes.
  • Code: 15.01.01:09, 15.01.02:09
  • Description: Drying PCA 0X has lost scan axis encoder signal. Retry. If this doesn’t work, run subsystem diagnostics, and if problem is confirmed call your support representative.. A scan-axis problem has been detected with lamps on. The drying subsystem is disconnected for safety reasons.
  • Causes: a. Scan-axis encoder problem b. Drying safety monitor hardware problems
  • Remedy: 1. Run scan-axis diagnostics. 2. Run drying diagnostics.
  • Code: 15.01.01:86, 15.01.02:86
  • Description: Drying PCA 0X Dryer PCA ID issue. Reinitialize carriage to recover the system. If this doesn’t work, run subsystem diagnostics, and if the problem is confirmed call your support representative.
  • Causes: The PCA is not providing the correct ID.
  • Remedy: 1. Check connections. 2. Run drying diagnostics. 3. Replace the drying PCA. See Drying PCA.
  • Code: 15.01.01:94
  • Description: Drying PCA 01 scan-axis timeout check failed. Reinitialize carriage to recover the system. If this doesn’t work, run subsystem diagnostics, and if the problem is confirmed call your support representative.
  • Causes: Hardware timeout check failed.
  • Remedy: 1. Check that the AC/AC power supply works properly. 2. Replace the drying PCA. See Drying PCA.
  • Code: 15.01.01:95
  • Description: Drying PCA 01 hardware supervisor check failed. Reinitialize carriage to recover the system. If this doesn’t work, run subsystem diagnostics, and if the problem is confirmed call your support representative.
  • Causes: Hardware timeout check failed.
  • Remedy: 1. Check that the AC/AC power supply works properly. 2. Replace the drying PCA. See Drying PCA.
  • Code: 15.01.02:94
  • Description: Drying PCA 02 scan-axis timeout check failed. Reinitialize carriage to recover the system. If this doesn’t work, run subsystem diagnostics, and if the problem is confirmed call your support representative.
  • Causes: Hardware timeout check failed.
  • Remedy: 1. Check that the AC/AC power supply works properly. 2. Replace the drying PCA. See Drying PCA.
  • Code: 15.01.02:95
  • Description: Drying PCA 02 hardware supervisor check failed. Reinitialize carriage to recover the system. If this doesn’t work, run subsystem diagnostics, and if the problem is confirmed call your support representative.
  • Causes: Hardware timeout check failed.
  • Remedy: 1. Check that the AC/AC power supply works properly. 2. Replace the drying PCA. See Drying PCA.
  • Code: 15.02.01:01, 15.02.02:01
  • Description: Bi-metal dryer 0X in error state. Reinitialize carriage to recover the system. If this doesn’t work, run subsystem diagnostics, and if the problem is confirmed call your support representative.
  • Causes: a. Bi-metal not properly connected to PCA b. Temperature too high in drying module
  • Remedy: 1. Reconnect properly. 2. Check temperature module temperature. 3. Replace bi-metal.