Mã lỗi HP Latex 3000 — Trang 31/42

Code: 43.01.00:01

Description: Vacuum blower not working in diagnostic test. Call support.
Causes: Vacuum tachometer is not giving feedback signal.
Remedy: 1. Run diagnostic. 2. Check connections. 3. Replace part.

Code: 43.02.00:04

Description: No feedback from the vacuum PCA. Check that substrate behavior in the print zone is OK. Run diagnostic when the job finishes.
Causes: a. Connections vacuum PCA failure b. Power management
Remedy: 1. Check connections. 2. Check e-box and e-cabinet. 3. Replace vacuum PCA.

Code: 43.03.00:04

Description: No feedback from the vacuum pressure sensor. Check that substrate behavior in the print zone is OK. Run diagnostic when the job finishes.
Causes: Connections pressure sensor vacuum PCA failure
Remedy: 1. Check connections. 2. Check pressure sensor EE and air connections. 3. Replace the sensor.

Code: 43.03.00:30

Description: Vacuum out of range. Run diagnostics. If the problem persists, call your service representative.
Causes: a. Air path open b. Pressure sensor inlet disconnected c. Power problem d. Pump problem
Remedy: 1. Run diagnostic. 2. Check connections. 3. Check EE and air connections.

Code: 43.03.00:83

Description: Vacuum sensor calibration fail. Check that substrate behavior in the print zone is OK. Run diagnostic when the job finishes.
Causes: a. Calibration process failure b. Cabling c. Sensor malfunction d. Vacuum pump failure
Remedy: 1. Repeat calibration process. 2. Check cabling and wiring. 3. Replace the sensor. 4. Replace the vacuum pump.

Code: 46.00.01:83 ... 46.00.01:83

Description: Primer X not calibrated. Run subsystem diagnostic. If the problem persists, call your support representative.
Causes: No value or zero read from NVM
Remedy: Run primer calibration.

Code: 46.01.01:01 ... 46.01.07:01

Description: Primer X signal failure. Run subsystem diagnostic. If the problem persists, call your support representative.
Causes: Current signal lost or current measure below reference threshold
Remedy: 1. Check connections. 2. Check carriage interconnect PCA 1 or 2, depending on the primer position reported. 3. Check the primer pump.

Code: 46.02.01:06 ... 46.02.07:06

Description: Primer X leakage detected. Reset primer latch and/or check o-rings. If the problem persists, run the subsystem diagnostic.
Causes: Current consumption measured below calibration value
Remedy: 1. Check primers, looking for leaks. 2. Check latches and o-rings. 3. Run subsystem diagnostic.