Description: Electrical PCA failure detected. Substrate-to-floor motor internal fault
Causes: a. Connector problem b. PSU problem c. Driver problem
Remedy: 1. Reload the substrate to clear the error. 2. Run the tension roller (MF) motor calibration/diagnostic test and follow the instructions provided in the test documentation.
Causes: a. Connection problem b. Motor problem c. EE problem
Remedy: 1. Reload the substrate to clear the error. 2. Reboot the printer. 3. Run the tension roller (MF) motor calibration/diagnostic test and follow the instructions provided in the test documentation.
Description: Tension roller motor’s driving voltage is too high.
Causes: a. Connection problem b. Substrate jam c. Transmission worn out d. Main Roller motor or encoder problem e. EE driver failure
Remedy: 1. Reload the substrate to clear the error. 2. Run the tension roller (MF) motor calibration/diagnostic test and follow the instructions provided in the test documentation.
Causes: a. Connection problem b. Substrate jam c. Transmission worn out d. Main roller motor or encoder problem e. EE driver failure
Remedy: 1. Reload the substrate to clear the error. 2. Run the tension roller (MF) motor calibration/diagnostic test and follow the instructions provided in the test documentation.
Description: Tension roller motor spinning too fast.
Causes: a. Encoder problem b. Motor problem
Remedy: 1. Reload the substrate to clear the error. 2. Run the tension roller (MF) motor calibration/diagnostic test and follow the instructions provided in the test documentation.
Description: Tension roller not moving.. Substrate to floor not moving.
Causes: a. Connection problem b. Substrate jam c. Spindle end cap worn out or blocked d. Substrate tension roller transmission problem e. Substrate tension roller motor f. EE driver failure
Remedy: 1. Reload the substrate to clear the error. 2. Run the tension roller (MF) motor calibration/diagnostic test and follow the instructions provided in the test documentation.
Remedy: 1. Ensure that the tension roller latches are closed on both sides. 2. Run the substrate path sensor check diagnostic to check that the sensor (on the capping station side) works correctly. 3. Replace the sensor.
Causes: a. Line of sight blocked b. Sensor failure, misconnection
Remedy: 1. Check that the take-up reel optical substrate sensor works correctly and that there is no object blocking its line of sight. 2. Run the substrate path sensor check diagnostic. 3. Replace the sensor.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.