Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi HP Latex 3000 — Trang 6/42

Code: 10.02.00:20

Description: E-cabinet temperature outside normal range. The ambient temperature is too high in the e-cabinet.
Causes: a. Room temperature too high b. Fan failure c. Ventilation grille filter clogged d. Ventilation grille blocked by an external factor
Remedy: None mandatory, warning only.

Code: 10.02.00:21

Description: E-cabinet temperature outside safe range. Ambient temperature too high in the e-cabinet.
Causes: a. Room temperature too high b. Fan failure c. Ventilation grille filter clogged d. Ventilation grille blocked by an external factor
Remedy: 1. Wait for cool-down. 2. Check the ventilation and room temperature. 3. Run subsystem diagnostic. 4. If the problem persists, call support.

Code: 10.02.00:41

Description: E-cabinet PCA overcurrent. The overcurrent protection for the actuators powered by the e-cabinet PCA has been triggered.
Causes: a. Fault in a 24 V component external to the PCA b. PCA fault
Remedy: 1. Inspect the safety circuit: safety engine adaptor PCA, contactors, e-stops, interlocks, and all associated cabling. 2. Inspect e-cabinet fan and cabling. 3. Rearm button light and cabling.

Code: 10.03.01:01

Description: E-cabinet PSU-1 no voltage or alarm signal asserted. PSU-1 not supplying voltage, or alarm signal is activated.
Causes: a. PSU-1 not receiving AC voltage b. PSU-1 DC output cable disconnected c. PSU-1 in fault mode (overcurrent, overvoltage, overtemperature) d. PSU-1 end of life e. PCA malfunction
Remedy: 1. Check ACB-7. 2. Run subsystem diagnostic. 3. Reboot the printer. 4. Check that the PSU-1 feedback LED is lit. 5. If the LED is lit, check the DC output cable and the PCA. 6. If the PSU-1 is still not working replace the PSU-1. See E-cabinet PSUs 1 to 4. 7. If the problem persists, call support

Code: 10.03.01:18

Description: E-cabinet PSU-1 voltage too high. PSU–1 voltage too high.
Causes: a. PSU-1 voltage too high b. PCA malfunction
Remedy: 1. Reboot the printer. 2. Run the subsystem diagnostic. 3. If the problem persists: a. Disconnect the DC output cable from the PCA. b. Measure the PSU-1 output voltage with a voltage meter. c. If lower than 42V +10%, it is likely a PCA malfunction. d. Otherwise adjust the PSU-1 output voltage through its adjustment potentiometer with the help of a voltage meter. Voltage must be within 42V +/- 5%. e. If the PSU-1 cannot be adjusted, replace the PSU. See E-cabinet PSUs 1 to 4.

Code: 10.03.01:19

Description: E-cabinet PSU-1 voltage too low. PSU–1 voltage too low.
Causes: a. PSU-1 voltage too low b. PCA malfunction
Remedy: 1. Reboot the printer. 2. Run the subsystem diagnostic. 3. If the problem persists: a. Disconnect the DC output cable from the PCA. b. Measure the PSU-1 output voltage with a voltage meter. c. If higher than 42V +10%, it is likely a PCA malfunction. d. Otherwise adjust the PSU-1 output voltage through its adjustment potentiometer with the help of a voltage meter. Voltage must be within 42V +/- 5%. e. If the PSU-1 cannot be adjusted, replace the PSU. See E-cabinet PSUs 1 to 4.

Code: 10.03.02:01

Description: E-cabinet PSU-2 no voltage or alarm signal asserted. PSU-2 not supplying voltage, or alarm signal is activated.
Causes: a. PSU-2 not receiving AC voltage b. PSU-2 DC output cable disconnected c. PSU-2 in fault mode (overcurrent, overvoltage, overtemperature) d. PSU-2 end of life e. PCA malfunction
Remedy: 1. Check ACB-6. 2. Run subsystem diagnostic. 3. Reboot the printer. 4. Check that the PSU-2 feedback LED is lit. 5. If the LED is lit, check the DC output cable and the PCA. 6. If the PSU-2 is still not working replace the PSU-2. See E-cabinet PSUs 1 to 4. 7. If the problem persists, call support.

Code: 10.03.02:10

Description: PSU_2 ground to earth voltage out of range. Run subsystem diagnostic. If the problem persists, call support.
Causes: The subsystem powered by this PSU may be not properly earthed.
Remedy: Check powered subsystem earthing.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie