Các lỗi thường gặp

Code :
  • Code: 10.02.00:20
  • Description: E-cabinet temperature outside normal range. The ambient temperature is too high in the e-cabinet.
  • Causes: a. Room temperature too high b. Fan failure c. Ventilation grille filter clogged d. Ventilation grille blocked by an external factor
  • Remedy: None mandatory, warning only.
  • Code: 10.02.00:21
  • Description: E-cabinet temperature outside safe range. Ambient temperature too high in the e-cabinet.
  • Causes: a. Room temperature too high b. Fan failure c. Ventilation grille filter clogged d. Ventilation grille blocked by an external factor
  • Remedy: 1. Wait for cool-down. 2. Check the ventilation and room temperature. 3. Run subsystem diagnostic. 4. If the problem persists, call support.
  • Code: 10.02.00:41
  • Description: E-cabinet PCA overcurrent. The overcurrent protection for the actuators powered by the e-cabinet PCA has been triggered.
  • Causes: a. Fault in a 24 V component external to the PCA b. PCA fault
  • Remedy: 1. Inspect the safety circuit: safety engine adaptor PCA, contactors, e-stops, interlocks, and all associated cabling. 2. Inspect e-cabinet fan and cabling. 3. Rearm button light and cabling.
  • Code: 10.03.01:01
  • Description: E-cabinet PSU-1 no voltage or alarm signal asserted. PSU-1 not supplying voltage, or alarm signal is activated.
  • Causes: a. PSU-1 not receiving AC voltage b. PSU-1 DC output cable disconnected c. PSU-1 in fault mode (overcurrent, overvoltage, overtemperature) d. PSU-1 end of life e. PCA malfunction
  • Remedy: 1. Check ACB-7. 2. Run subsystem diagnostic. 3. Reboot the printer. 4. Check that the PSU-1 feedback LED is lit. 5. If the LED is lit, check the DC output cable and the PCA. 6. If the PSU-1 is still not working replace the PSU-1. See E-cabinet PSUs 1 to 4. 7. If the problem persists, call support
  • Code: 10.03.01:18
  • Description: E-cabinet PSU-1 voltage too high. PSU–1 voltage too high.
  • Causes: a. PSU-1 voltage too high b. PCA malfunction
  • Remedy: 1. Reboot the printer. 2. Run the subsystem diagnostic. 3. If the problem persists: a. Disconnect the DC output cable from the PCA. b. Measure the PSU-1 output voltage with a voltage meter. c. If lower than 42V +10%, it is likely a PCA malfunction. d. Otherwise adjust the PSU-1 output voltage through its adjustment potentiometer with the help of a voltage meter. Voltage must be within 42V +/- 5%. e. If the PSU-1 cannot be adjusted, replace the PSU. See E-cabinet PSUs 1 to 4.
  • Code: 10.03.01:19
  • Description: E-cabinet PSU-1 voltage too low. PSU–1 voltage too low.
  • Causes: a. PSU-1 voltage too low b. PCA malfunction
  • Remedy: 1. Reboot the printer. 2. Run the subsystem diagnostic. 3. If the problem persists: a. Disconnect the DC output cable from the PCA. b. Measure the PSU-1 output voltage with a voltage meter. c. If higher than 42V +10%, it is likely a PCA malfunction. d. Otherwise adjust the PSU-1 output voltage through its adjustment potentiometer with the help of a voltage meter. Voltage must be within 42V +/- 5%. e. If the PSU-1 cannot be adjusted, replace the PSU. See E-cabinet PSUs 1 to 4.
  • Code: 10.03.02:01
  • Description: E-cabinet PSU-2 no voltage or alarm signal asserted. PSU-2 not supplying voltage, or alarm signal is activated.
  • Causes: a. PSU-2 not receiving AC voltage b. PSU-2 DC output cable disconnected c. PSU-2 in fault mode (overcurrent, overvoltage, overtemperature) d. PSU-2 end of life e. PCA malfunction
  • Remedy: 1. Check ACB-6. 2. Run subsystem diagnostic. 3. Reboot the printer. 4. Check that the PSU-2 feedback LED is lit. 5. If the LED is lit, check the DC output cable and the PCA. 6. If the PSU-2 is still not working replace the PSU-2. See E-cabinet PSUs 1 to 4. 7. If the problem persists, call support.
  • Code: 10.03.02:10
  • Description: PSU_2 ground to earth voltage out of range. Run subsystem diagnostic. If the problem persists, call support.
  • Causes: The subsystem powered by this PSU may be not properly earthed.
  • Remedy: Check powered subsystem earthing.
‹ First  < 3 4 5 6 7 8 9 >  Last ›
popup

Số lượng:

Tổng tiền:

Danh mục