Description: Contactor K3 does not switch state. The contactor K-3 is closed when it should be open, or open when it should be closed.
Causes: a. Contactor fault b. Feedback cable fault (from K-3 contacts 33/34 to e-cabinet PCA contact connector) c. E-cabinet PCA fault
Remedy: 1. Restart the printer. If the problem does not repeat, it is probably a firmware glitch. 2. If the problem persists, check that the cable from the 33/34 contacts of K-3 to the e-cabinet PCA is not damaged. If it is damaged, replace the cable. This affects the other contactors as there is only one feedback cable for all of them. 3. If the problem persists, replace the K-3 contactor. 4. If the problem persists, replace the e-cabinet PCA. See E-cabinet PCA.
Code: 10.01.04:01
Description: Contactor K4 does not switch state. The contactor K-4 is closed when it should be open, or open when it should be closed.
Causes: a. Contactor fault b. Feedback cable fault (from K-4 contacts 33/34 to e-cabinet PCA contact connector) c. E-cabinet PCA fault
Remedy: 1. Restart the printer. If the problem does not repeat, it is probably a firmware glitch. 2. If the problem persists, check that the cable from the 33/34 contacts of K-4 to the e-cabinet PCA is not damaged. If it is damaged, replace the cable. This affects the other contactors as there is only one feedback cable for all of them. 3. If the problem persists, replace the K-4 contactor. 4. If the problem persists, replace the e-cabinet PCA. See E-cabinet PCA.
Code: 10.02.00:01
Description: E-cabinet PCA malfunction. Run subsystem diagnostic. If the problem persists, call support representative. A malfunction on the e-cabinet PCA has been detected.
Causes: SMT fuse blown, component failure
Remedy: 1. Run subsystem diagnostic. 2. Replace the e-cabinet PCA. See E-cabinet PCA. 3. If the problem persists, call support.
Code: 10.02.00:03
Description: E-cabinet PCA not supported version. PCA wrong version
Causes: a. Wrong version of the PCA installed b. PCA malfunction
Remedy: 1. Run subsystem diagnostic. 2. Replace the PCA with the appropriate revision. See E-cabinet PCA. 3. If the problem persists, call support.
Code: 10.02.00:04
Description: E-cabinet to e-box communication failure I2C communication malfunction. The e-box cannot communicate with the e-cabinet.
Causes: a. Communication cable not connected or misconnected b. PSU-2 not working c. PCA malfunction
Remedy: 1. Run subsystem diagnostic. 2. Find the root cause and correct it. 3. If the problem persists, call support.
Code: 10.02.00:11
Description: E-cabinet PCA 5V to ground voltage out of range. E-cabinet PCA 5V to ground voltage is out of range.
Causes: E-cabinet PCA malfunction
Remedy: 1. Run subsystem diagnostic. 2. Replace the e-cabinet PCA. See E-cabinet PCA. 3. If the problem persists, call support.
Code: 10.02.00:13
Description: E-cabinet PCA 8V to ground voltage out of range E-cabinet PCA 8V to ground voltage out of range.
Causes: E-cabinet PCA malfunction
Remedy: 1. Run subsystem diagnostic. 2. Replace the e-cabinet PCA. See E-cabinet PCA. 3. If the problem persists, call support.
Code: 10.02.00:15
Description: E-cabinet PCA replaceable fuse blown. The glass fuse on the inner face of the e-cabinet PCA (F24) has blown.
Causes: a. Fuse blown b. PCA fault
Remedy: 1. Replace the fuse. 2. If the problem persists, check for short-circuits: a. Safety circuit (Safety Engine Adaptor PCA, contactors, e-stops, Interlocks, and all associated cabling). b. E-cabinet fan and cabling. c. Rearm button light and cabling.