Causes: Detect Line Sync incorrectly. Connection of connecters between ESS PWB J32 and MCU PWB J14, disconnection of Flat Cable, or loose connection. Replace ESS PWB if no problem with Flat Cable.
Causes: The finish code is not found in the compressed data (FF02) when depressing the data in specified size. When it is not recovered by powering OFF and On, execute the following. In case of that the specific documents cause the trouble. The possibility of software problem is high. 1. Changing print mode (normal/high quality/high resolution) may print out. 2. Changing RAM size may print out. A. Change RAM size to install B. Change the used size of RAM (Change the setting of port, or received buffer size) In case of that the most of documents cause the trouble. The possibility of hardware problem is high. 1. Change RAM 2. Execute the DC355 DIAG test, and replace HDD if the trouble is not recovered. 3. Replace ESS PWB
Causes: No response from IOT PWB to ESS PWB sending.MCU PWB J14, disconnection of Flat Cable, or loose connection. Replace ESS PWB if no problem with Flat Cable. When it is not recovered yet, replace MCU PWB.
Causes: ESS PWB detects DLL send error. MCU PWB J14, disconnection of Flat Cable, or loose connection. Replace ESS PWB if no problem with Flat Cable. When it is not recovered yet, replace MCU PWB.