Các lỗi thường gặp

Code :
  • Code: SC664-03
  • Description: ASIC on the IOB SRAM program expansion error. ASIC on the IOB program startup error
  • Causes: • Noise • Hardware defection
  • Remedy: • Replace the imaging IOB and paper transport IOB • Check the harness
  • Code: SC665-01
  • Description: FFC set detection. FFC set error is detected by port lead and AD value read-out BCU-IPU connection error
  • Causes: • SC display • LED blink mode correction on BCU
  • Remedy:
  • Code: SC665-02
  • Description: FFC set detection. FFC set error is detected by port lead and AD value read-out BCU - imaging IOB connection error
  • Causes: SC display
  • Remedy:
  • Code: SC665-03
  • Description: FFC set detection. FFC set error is detected by port lead and AD value read-out BCU - paper transport IOB connection error
  • Causes: SC display
  • Remedy:
  • Code: SC669
  • Description: EEPROM Communication Error
  • Causes: • Electrical noise • EEPROM not connected fully • EEPROM not installed • EEPROM damaged • BCU damaged
  • Remedy: • Turn the power off/on • Reconnect the EEPROM • Replace the EEPROM • Replace the BCU
  • Code: SC670-00
  • Description: Engine start up error. • Case 1 • /ENGRDY signal was not asserted when the machine was turned on or returned from energy saver mode. • /IPURDY signal was not asserted when the machine was turned on or returned from energy saver mode. • EC response was not received within specified time from power on. • PC response was not received within specified time from power on. • SC response was not received within specified time from power on. • Writing to Rapi driver failed (the other party not found through PCI). • Case 2 • Unexpected down status was detected after /ENGRDY assertion.
  • Causes: • Case 1 • Engine board does not start up. • Case 2 • Engine board reset unexpectedly.
  • Remedy: Check the connection between the engine board and the controller board. • If it is always reproduced, replace the engine board. If the problem persists, consider replacing the controller board or other boards between them. • If reproducibility is low, multiple causes are to be considered, such as software, engine board, controller board, and PSU.
  • Code: SC672-10
  • Description: Controller start up error After the machine was powered on, communication between the controller and the operation panel was not established.
  • Causes: • Controller stalled • Board installed incorrectly • Controller board defective • Operation panel connector loose, broken, or defective • Controller late
  • Remedy: • Turn the main power off/on. • Check the connection of the controller board. • Replace the controller board. • Check the control panel harness.
  • Code: SC672-11
  • Description: Controller start up error After the machine was powered on, communication between the controller and the operation panel was not established, or communication with controller was interrupted after a normal startup.
  • Causes: • Controller stalled • Board installed incorrectly • Controller board defective • Operation panel connector loose, broken, or defective • Controller late
  • Remedy: • Turn the main power off/on. • Check the connection of the controller board. • Replace the controller board. • Check the control panel harness.