Các lỗi thường gặp

Code :
  • Code: SC672-12
  • Description: Controller start up error Communication with controller was interrupted after a normal startup.
  • Causes: • Controller stalled • Board installed incorrectly • Controller board defective • Operation panel connector loose, broken, or defective • Controller late
  • Remedy: • Turn the main power off/on. • Check the connection of the controller board. • Replace the controller board. • Check the control panel harness.
  • Code: SC672-13
  • Description: Controller start up error The operation panel detected that the controller is down.
  • Causes: • Controller stalled • Board installed incorrectly • Controller board defective • Operation panel connector loose, broken, or defective • Controller late
  • Remedy: • Turn the main power off/on. • Check the connection of the controller board. • Replace the controller board. • Check the control panel harness.
  • Code: SC672-99
  • Description: Controller start up error The operation panel software ended abnormally.
  • Causes: • Controller stalled • Board installed incorrectly • Controller board defective • Operation panel connector loose, broken, or defective • Controller late
  • Remedy: • Turn the main power off/on. • Check the connection of the controller board. • Replace the controller board. • Check the control panel harness.
  • Code: SC681
  • Description: Toner Cartridge: ID Chip Communication Error • When abnormality occurs at cable connection • When error notification was received during communication with the tag and operation is not resumed after 3 retries.
  • Causes: There was an error during (wired) communication with the ID chip on the toner bottle.
  • Remedy: • Replace the development unit SC branch number: 01, 06, 11, 16, 21, 26, 31, 36: K 02, 07, 12, 17, 22, 27, 32, 37: M 03, 08, 13, 18, 23, 28, 33, 38: C 04, 09, 14, 19, 24, 29, 34, 39: Y
  • Code: SC682
  • Description: PCU: ID Chip Communication Error
  • Causes: When error notification was received during communication with the tag and operation is not resumed after 3 retries. • HST sensor defective • EEPROM defective • PCU set error 01 - 04 • Device ID data corruption 06 - 09 • Connection fault (bus disconnect, etc.) 11 - 14 • No ID chip 16 – 19, 21 – 24, 26 - 29 • Noise 31 - 34, 36 - 39 • Software defection
  • Remedy: Replace the PCU
  • Code: SC687-00
  • Description: PER Not Received Error
  • Causes: Unable to receive the PER command from the controller.
  • Remedy: Replace the BCU
  • Code: SC700-01
  • Description: Base Plate Lift Motor Error (1-pass ADF) Even if the base plate motor is rotated in the base plate ascent direction, the base plate paper feed correct position sensor does not detect. Even if the base plate motor is rotated in the base plate descent direction, the base plate home position sensor does not detect.
  • Causes: • Base plate paper feed correct position sensor error (output error) • Base plate home position sensor error (output error) • Base plate motor error (does not rotate) • Controller error
  • Remedy: -01, 02 • Check the sensor harness and motor harness connection • Replace the sensor harness and motor harness • Replace the sensor • Replace the motor • Replace the controller -04, 05, 06, 07, 09 • Check the harness connection • Replace the harness • Replace the motor 5. Troubleshooting
  • Code: SC700-02
  • Description: Original Pick-up Error (1-pass ADF) Even if the pick up arm motor is rotated, the pick up arm home position sensor does not detect.
  • Causes: • Pick-up home position sensor error (output error) • Pick-up motor error (does not rotate) • Controller error
  • Remedy: -01, 02 • Check the sensor harness and motor harness connection • Replace the sensor harness and motor harness • Replace the sensor • Replace the motor • Replace the controller -04, 05, 06, 07, 09 • Check the harness connection • Replace the harness • Replace the motor 5. Troubleshooting