Các lỗi thường gặp

Code :
  • Code: SC833
  • Description: Self-diagnostic error: Engine I/F ASIC CTL [0F30] ASIC (Mandolin) for engine control could not be detected. After the PCI was configured, the device ID for the ASIC could not be checked. •X Defective ASIC (Mandolin) for system control •X Defective North Bridge and AGPI/F •X Replace the motherboard (engine I/F board). [50B1] Could not initialize or read the bus connection. •X Defective connection bus •X Defective SSCG •X Replace the motherboard (engine I/F board). [50B2] SSCG register value was incorrect. •X Defective connection bus •X Defective SSCG •X Replace the motherboard (engine I/F board).
  • Causes:
  • Remedy:
  • Code: SC834
  • Description: Self-diagnostic error: optional memory[5101] An error occurred after write/verify check for optional RAM on the motherboard.
  • Causes: •X Defective memory device
  • Remedy: •X Replace the motherboard (engine I/F board).
  • Code: SC838
  • Description: Self-diagnostic error: Clock generator CTL [2701] A verify error occurred when setting data was read from the clock generator via the I2C bus
  • Causes: •X Defective clock generator •X Defective I2C bus •X Defective I2C port on the CPU
  • Remedy: •X Replace the controller board.
  • Code: SC840
  • Description: EEPROM access error CTL A read error occurred during I/O processing. The failure of the 3rd attempt to read caused this error.
  • Causes: •X Defective EEPROM
  • Remedy: •X Replace the EEPROM
  • Code: SC841
  • Description: EEPROM read error CTL Mirrored data of the EEPROM is different from the original data in EEPROM.
  • Causes: •X Data in the EEPROM was overwritten for some reason.
  • Remedy: •X Cycle the machine off/on
  • Code: SC842
  • Description: Nand-Flash updating verification error CTL A write error for the module written in Nand-Flash occurred while the remote ROM and ROM were being updated.
  • Causes: •X Damaged Nand-Flash
  • Remedy: •X Cycle the machine off/on
  • Code: SC850
  • Description: Network I/F error
  • Causes: •X Network not operating.
  • Remedy: •X Cycle the machine off/on
  • Code: SC851
  • Description: IEEE1394 I/F error
  • Causes: There is an incorrect setting in the driver that prevented correct operation of the interface.
  • Remedy: •X Check and correct the driver settings •X Network (PHY) LINK module defective •X PCI interface defective •X IEEE1394 I/F board defective •X Controller board defective
‹ First  < 10 11 12 13 14 15 16 >  Last ›