Description: Scanner Automatic Adjustment Error Automatic adjustment of the CIS failed at power on.
Causes: • Standard white strips dirty or not platen white plate installed improperly • CIS LED defective and not lighting • CIS-to-PSU harness connector loose, disconnected, or defective • CIS-to-SIPU harness connector loose, disconnected, or defective • CIS defective • MCU defective • SIF defective • SIPU defective
Description: SIPU Error 1: FPGA Configuration Error. At power on, or when the machine returned from energy save mode, the FPGA Flash Program did not configure correctly. -or- An SIPU error occurred during the FPGA check after three attempts.
Description: SIPU Error 2: Ri2005 Chip Failure At power on, or when the machine returned from energy save mode, an SIPU error occurred during Ri2500 access (Ri2500 did not respond within 5 ms).
Description: SIPU Error 3: Ri2001A Chip Failure At power on, or when the machine returned from energy save mode, the Ri2001A chip on the SIPU failed (Ri2001A did not respond within 5 ms).
Description: SIPU Error 4: Cetus Configuration Error At power on, or when the machine returned from energy save mode, Cetus configuration failed after three attempts within 810 ms
Description: Gray Balance Adjustment Error The value for gray balance was detected out of range after gray adjustment.
Causes: If cycling the machine power off/on does not solve the problem: • Clean the platen white plate • Clean the exposure glass • CIS-SIF harnesses loose, broken, defective • SIF-SIPU harnesses loose, broken, defective • SIF defective • CIS defective • SIPU defective
Remedy:
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.