  • Code: 101
  • Description: Scanner Lamp Error At power on the scan lamp trigger remained off.
  • Causes: • CIS-to-SIPU harness loose, disconnected, or defective • CIS-to-SIF-to-SIPU harness loose, disconnected, or defective • CIS, SIPU defective
  • Remedy:
  • Code: 143
  • Description: Scanner Automatic Adjustment Error Automatic adjustment of the CIS failed at power on.
  • Causes: • Standard white strips dirty or not platen white plate installed improperly • CIS LED defective and not lighting • CIS-to-PSU harness connector loose, disconnected, or defective • CIS-to-SIPU harness connector loose, disconnected, or defective • CIS defective • MCU defective • SIF defective • SIPU defective
  • Remedy:
  • Code: 144
  • Description: SIF Communication Error SIF serial transmission did not begin within 1 sec. after power on. No communication with SIF.
  • Causes: • MCU defective • SIF defective • SIF-to-MCU harness connector loose, disconnected, or defective • SIPU defective
  • Remedy:
  • Code: 161-1
  • Description: SIPU Error 1: FPGA Configuration Error. At power on, or when the machine returned from energy save mode, the FPGA Flash Program did not configure correctly. -or- An SIPU error occurred during the FPGA check after three attempts.
  • Causes: • SIPU defective
  • Remedy:
  • Code: 161-2
  • Description: SIPU Error 2: Ri2005 Chip Failure At power on, or when the machine returned from energy save mode, an SIPU error occurred during Ri2500 access (Ri2500 did not respond within 5 ms).
  • Causes: • SIPU defective
  • Remedy:
  • Code: 161-3
  • Description: SIPU Error 3: Ri2001A Chip Failure At power on, or when the machine returned from energy save mode, the Ri2001A chip on the SIPU failed (Ri2001A did not respond within 5 ms).
  • Causes: • SIPU defective
  • Remedy:
  • Code: 161-4
  • Description: SIPU Error 4: Cetus Configuration Error At power on, or when the machine returned from energy save mode, Cetus configuration failed after three attempts within 810 ms
  • Causes: • SIPU defective
  • Remedy:
  • Code: 186
  • Description: Gray Balance Adjustment Error The value for gray balance was detected out of range after gray adjustment.
  • Causes: If cycling the machine power off/on does not solve the problem: • Clean the platen white plate • Clean the exposure glass • CIS-SIF harnesses loose, broken, defective • SIF-SIPU harnesses loose, broken, defective • SIF defective • CIS defective • SIPU defective
  • Remedy: