Các lỗi thường gặp

Code :
  • Code: 543
  • Description: Fusing Temperature: Error 1
  • Causes: The circuit on the MCU that monitors the temperature of the board detected a fusing temperature of 230C (446F) for longer than 2 sec.
  • Remedy: • MCU defective
  • Code: 544
  • Description: Fusing Temperature: Error 2 (Hardware Detection)
  • Causes: The fusing thermistor that monitors the temperature of the hot roller detected a fusing temperature of 235C (455F), due to a Triac short which interfered with fusing temperature control.
  • Remedy: • MCU defective • PSU defective • Fusing unit defective
  • Code: 545
  • Description: Fusing Lamp Overheated: Error 2 After the hot roller reached the ready temperature, the fusing lamp stayed on at full power for 50 sec. while the hot roller was not rotating.
  • Causes: • Hot roller thermistor not positioned correctly • Fusing lamp harness loose, disconnected, defective • MCU defective
  • Remedy:
  • Code: 546
  • Description: Fusing Temperature Errors The machine detected that the fusing temperature was fluctuating out of range for more than 60 sec. (7 readings detected temperature fluctuating more than ±20C)
  • Causes: • Thermistor connection loose, disconnected, defective • Hot roller thermistor not positioned correctly • Fusing lamp connections loose, disconnected, defective • MCU defective
  • Remedy:
  • Code: 547
  • Description: Zero-Cross Signal Errors This error occurs if the machine fails to detect 50/60 Hz on the power supply line. Note: The zero-cross signal from the ac power supply generates a trigger pulse to control the power supply of power. (It automatically detects 50/60 Hz.)
  • Causes: • Check that the frequency of the power supply to the machine is correct • PSU defective • MCU defective
  • Remedy:
  • Code: 551
  • Description: Pressure roller center thermistor error 1 During the hot roller temperature control sequence, or while the hot roller and pressure roller were rotating, the pressure roller center thermistor measured a value higher than 3.3V 10 consecutive times at 600 ms intervals.
  • Causes: • Pressure roller center thermistor not positioned properly • Pressure roller center thermistor connector loose, broken, defective • Pressure roller center thermistor defective • MCU defective
  • Remedy:
  • Code: 553
  • Description: Pressure roller center thermistor error 2 During the hot roller temperature control sequence, the pressure roller center thermistor measures a value lower than 0.2V.
  • Causes: • Pressure roller center thermistor not positioned properly • Pressure roller center thermistor connector loose, broken, defective • Pressure roller center thermistor defective • MCU defective
  • Remedy:
  • Code: 557
  • Description: Applied zero-cross waveform error The applied power ac frequency was detected less than 66 Hz more than 10 times.
  • Causes: • Noise on the ac power supply line
  • Remedy:
 < 1 2 3 4 5 6 7 >  Last ›
popup

Số lượng:

Tổng tiền:

Danh mục