Các lỗi thường gặp

Code :
  • Code: SC994
  • Description: Operation Panel Management Records Exceeded CTL An error occurred because the number of records exceeded the limit for images managed in the service layer of the firmware. This can occur if there are too many application screens open on the operation panel.
  • Causes: • No action required because this SC does not interfere with operation of the machine.
  • Remedy:
  • Code: SC997
  • Description: Cannot select application function CTL An application did not start after the user pushed the correct key on the operation panel.
  • Causes: • Software bug • A RAM or DIMM option required for the application is not installed or not installed correctly.
  • Remedy:
  • Code: SC998
  • Description: Application cannot start CTL Register processing does not operate for an application within 60 s after the machine power is turned on. No applications start correctly, and all end abnormally.
  • Causes: • Software bug • A RAM or DIMM option needed for the application not installed, or not installed correctly • Controller board defective
  • Remedy: