Description: Data Encryption Error 1. These are errors of the HDD Data Encryption Option.
Causes: 0 Key Acquisition Key could be acquired. • Replace the controller board 1 HDD Key Setting Error The key was acquired but the HDD could not be set. • Turn the machine power off/on several times. • Replace the controller board. 2 NVRAM Read Error NVRAM data conversion failed (mismatch with nvram.conf). • Replace the NVRAM 30 NVRAM Before Replace Error DFU. May occur during development. • Turn the machine power off/on several times. • Replace the controller board. 31 Other Error An unexpected error occurred while data was being converted. This error is the same as SC991. See SC991 below.
Description: Data Encryption Error 2. These are errors of the HDD Data Encryption Option D377. 8 HDD Check Error Data conversion was attempted with no HDD unit present. • Confirm that HDD unit installed correctly • Initialize HDD with SP5832-1 Note: After installation, a new HDD should be formatted with SP5832-1 9 Power Loss During Data Conversion Data conversion stopped before NVRAM/HDD data was converted. • Format HDD with SP5832-1 10 Data Read Command Error More than two illegal DMAC communications were returned.
Causes: • HDD defective • Format HDD with SP5832-1 • Replace HDD
Description: HDD startup error at power on CTL HDD is connected but a driver error is detected. -or- The driver does not respond with the status of the HDD within 30 s.
Causes: • HDD is not initialized • Level data corrupted • HDD is defective
Description: HDD re-try failure CTL At power on the HDD was detected. Power supply to the HDD was interrupted after the system entered the energy save mode, but after the HDD was awakened from the energy save mode it did not return to the ready status within 30 sec.
Causes: • Harness between HDD and controller board disconnected, defective • HDD power connector disconnected • HDD defective • Controller board defective
Description: HDD data read failure CTL The data written to the HDD cannot be read normally, due to bad sectors generated during operation.
Causes: • HDD defective
Remedy: • If the bad sectors are generated at the image partition, the bad sector information is written to NVRAM. • The next time the HDD is accessed, these bad sectors will not be accessed for read/write operation. The HDD will probably require replacement soon.
Description: HDD data CRC error CTL During HDD operation, the HDD cannot respond to a CRC error query. Data transfer did not execute normally while data was being written to the HDD.
Description: SD card error 1: Confirmation error CTL The machine detected an electronic license error in the application on the SD card in the controller slot immediately after the machine was turned on.
Causes: • Program missing from the SD card
Remedy:
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.