Description: IOT Speed Change SW Fail An irregularity was detected in the middle of the IOT speed change procedure. 1. Failed to transition to Diag Mode 2. Failed at DC132 3. Failed at SEEP-ROM R/W 4. Failed at reboot
Causes: • Image Processor PWB, PL 12.4.1
Remedy: 1. Perform firmware upgrade (Firmware Update). 2. If the problem persists, replace the I/P PWB PWB).
Description: ASIC Fail (Panther)/ 124-337 ESS Standard RAM Error RAM error has occurred due to one of the following problems. • Server error was detected. • An ESS On Board Standard RAM error was detected. • 124-333: Panther Error • 124-337: ESS Standard RAM (Standard ROM) Error
Causes: • 1 GB DDR2 DIMM, PL 12.4.2
Remedy: 1. Reinstall the NVRAM). 2. If the problem still persists, go to Common System Fail.
Description: • 124-341: One of CRUM destinations is different from the others (IOT). • 124-351: One of CRUM OEM destinations is different from the others (IOT). • 124-361: One of CRUM Enable/Disable settings is different from the others (IOT).
Causes: • MCU PWB, PL 12.1.15
Remedy: 1. Perform DC132 Machine Serial Number Settings, SYS 1. 2. If the problem persists, replace the MCU PWB.
Description: CRUM error has occurred due to one of the following problems. • At least one of the CRUM Destination Value that is stored in the 3 locations is not matched (the contents stored in the Controller PWB do not match). • At least one of the CRUM OEM Destination that is stored in the 3 locations is not matched (the contents stored in the Controller PWB do not match). • At least one of the CRUM Enabled/ Disabled that is stored in the 3 locations is not matched (the contents stored in the Controller PWB do not match). • 124-342: One of CRUM destinations is different from the others (SYS 1). • 124-352: One of CRUM OEM destinations is different from the others (SYS 1). • 124-362: One of CRUM Enable/Disable settings is different from the others (SYS 1).
Causes: • I/P PWB, PL 12.4.1
Remedy: 1. Perform DC132 Machine Serial Number Settings, MCU PWB. 2. If the problem persists, replace the I/P PWB PWB).
Description: CRUM error has occurred due to one of the following problems. • At least one of the CRUM Destination Value that is stored in the 3 locations is not matched (the contents stored in the Controller PWB do not match). • At least one of the CRUM OEM Destination that is stored in the 3 locations is not matched (the contents stored in the Controller PWB do not match). • At least one of the CRUM Enabled/Disabled that is stored in the 3 locations is not matched (the contents stored in the Controller PWB do not match). • 124-343: One of CRUM destinations is different from the others (SYS 2). • 124-353: One of CRUM OEM destinations is different from the others (SYS 2). • 124-363: One of CRUM Enable/Disable settings is different from the others (SYS 2).
Causes: • I/P PWB, PL 12.4.1
Remedy: 1. Perform DC132 Machine Serial Number Settings, SYS 2. 2. If the problem persists, replace the I/P PWB PWB).
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin