Mã lỗi Xerox Phaser 7100 — Trang 19/20

Code: 124-344, 124-346

Description: Billing error has occurred due to one of the following problems. • The Billing Meter Types that are stored in multiple locations are all different. • The Billing Count Types that are stored in multiple locations are all different. • 124-344: Billing Meter Type Fail (different at all 3 locations) • 124-346: Billing Count Type Fail (different at all 3 locations)
Causes: • MCU PWB, PL 12.1.15 • Image Processor PWB, PL 12.4.1
Remedy: 1. Replace the MCU PWB. 2. If the problem persists, replace the I/P PWB PWB).

Code: 124-345

Description: Billing Meter Type Restoration Fail When at least one Billing Meter Type is not matched and the machine automatic correction has failed to correct the problem.
Causes: • MCU PWB, PL 12.1.15 • I/P PWB, PL 12.4.1
Remedy: 1. Perform DC131 NVM Read/ Write to compare the following NVM values. • If the values of 720-002 and 720-062 are the same, replace the MCU PWB. • If the values are different, replace the I/P PWB PWB).

Code: 124-347

Description: Billing Count Type Restoration Fail When at least one Billing Count Type is not matched and the machine automatic correction has failed to correct the problem.
Causes: • MCU PWB, PL 12.1.15 • I/P PWB, PL 12.4.1
Remedy: 1. Perform DC131 NVM Read/ Write to compare the following NVM values. • If the values of 720-052 and 720-063 are the same, replace the MCU PWB. • If the values are different, replace the I/P PWB PWB).

Code: 124-348

Description: All Model Break Points Mismatch The Model Break Points that are stored in multiple locations are all different.
Causes: • MCU PWB, PL 12.1.15 • Image Processor PWB, PL 12.4.1
Remedy: 1. Replace the MCU PWB. 2. If the problem persists, replace the I/P PWB PWB).

Code: 124-349

Description: Model Break Point Restoration Fail When at least one Model Break Point is not matched and the machine automatic correction has failed to correct the problem.
Causes: • MCU PWB, PL 12.1.15 • I/P PWB, PL 12.4.1
Remedy: 1. Perform DC131 NVM Read/ Write to compare the following NVM values. • If the values of 720-057 and 720-064 are the same, replace the MCU PWB. • If the values are different, replace the I/P PWB PWB).

Code: 124-350

Description: CRUM OEM Fail All Although the CRUM OEM Destination that is stored in the 3 locations are matched, their values are not set (0).
Causes: • MCU PWB, PL 12.1.15
Remedy: 1. Replace the MCU PWB.

Code: 124-360

Description: CRUM Validation/ 124-390 CRUM OEM Fail All CRUM error has occurred due to one of the following problems. • Although the CRUM Enabled/ Disabled that is stored in the 3 locations are matched, their values are not set (0). • Although the CRUM OEM Destination that is stored in the 3 locations are matched, their values are not set (0) • 124-360: All three CRUM Enable/ Disable settings are not set (0 or different values are set). • 124-390: All three CRUM OEM destinations are not set (0 or different values are set). #Case-(2)
Causes: • MCU PWB, PL 12.1.15
Remedy: 1. Replace the MCU PWB.

Code: 124-380

Description: CRUM Market Fail All (2) Although the CRUM Destination Value that is stored in the 3 locations are matched, their values are not set (0).
Causes: • MCU PWB, PL 12.1.15 • Image Processor PWB, PL 12.4.1
Remedy: 1. Replace the MCU PWB. 2. If the problem persists, replace the I/P PWB PWB).