Remedy: • Turn the power off at the rear of the printer and disconnect the power cord. Reconnect the power cord and turn on the printer. • Check that the Vacuum Fan cable is not damaged and is correctly connected to the Vacuum Driver PCA and to both Vacuum Motors. • Check that the Interconnect to Vacuum Driver cable is not damaged and correctly connected to Vacuum Driver PCA and to the Interconnect PCA. • Replace the Vacuum Fan
Code: 43:11
Description: Vacuum Fan
Causes: Vacuum Fan PCA cable does not seem to be connected
Remedy: • Check that the Interconnect PCA to Vacuum Fan cable is not damaged. • Check that the Interconnect PCA to Vacuum Fan cable is correctly connected to the Interconnect PCA and the Vacuum Fan PCA. • If the problem persists, replace the Interconnect PCA to Vacuum Fan cable
Code: 44.2:10
Description: Aerosol Fan
Causes: Right Aerosol Fan stopped or spinning at lower speed
Remedy: • Turn the power off at the rear of the printer and disconnect the power cord. Reconnect the power cord and turn on the printer. • Check that the Right Aerosol Fan cable is not damaged and is correctly connected to the PrintMech PCA. • Check that there is no obstacle blocking the fan. • Replace the Right Aerosol Fan
Code: 44.4:10
Description: Aerosol Fan
Causes: Right Aerosol Fan Filter blocked
Remedy: • Turn the power off at the rear of the printer and disconnect the power cord. Reconnect the power cord and turn on the printer. • Check that the Right Aerosol Fan cable is not damaged and is correctly connected to the PrintMech PCA. • If the system error persists, replace the Aerosol Filter
Code: 45:03
Description: Rewinder
Causes: Rewinder servo shutdown
Remedy: • Turn the power off at the rear of the printer and disconnect the power cord. Reconnect the power cord and turn on the printer. • Open the Window and check for any visible obstacles restricting the movement of the Rewinder. If there is a wrinkled mass of paper inside the paper path, open the Rear Door and clear the obstruction. • Replace the Rewinder Motor
Code: 46:03
Description: Primer
Causes: Primer servo shutdown
Remedy: • Check that the Primer Arm is not damaged and there are no obstacles in its way. • Turn the power off at the rear of the printer and disconnect the power cord. Reconnect the power cord and turn on the printer. • Replace the Primer Assembly
Code: 46:13
Description: Primer
Causes: Primer test distance failed
Remedy: • Check that the Primer Arm is not damaged and there are no obstacles in its way. • Turn the power off at the rear of the printer and disconnect the power cord. Reconnect the power cord and turn on the printer. • Replace the Primer Assembly
Code: 50.1:10
Description: OMAS
Causes: OMAS Module communication failure
Remedy: • Turn the power off at the rear of the printer and disconnect the power cord. Reconnect the power cord and turn on the printer. • Check that the printer has the latest firmware version. If not, update the firmware to the latest version. • Check that the OMAS Controller to OMAS Sensor cable is not damaged and is correctly connected to the OMAS Controller Card and the OMAS Module. • Replace the OMAS Module