Description: Drying fan array 0X in error state. Reinitialize carriage to recover the system. If this doesn’t work, run subsystem diagnostics, and if the problem is confirmed call your support representative.
Causes: At least one fan is not spinning (blocked or broken).
Description: Drying fan array 0X current value too low. Reinitialize carriage to recover the system. Replace affected part.
Causes: a. At least one fan is not connected to the fan harness. b. At least one fan is failing. c. A fan fuse is blown. d. There is an error in a pressure servo (incorrect PWM).
Remedy: 1. Visually inspect the fan array harness. 2. Replace the fuse. 3. Reset or restart the system.
Description: Drying PCA 0X lamps disabled. Reinitialize carriage to recover the system. If this doesn’t work, run subsystem diagnostics, and if the problem is confirmed call your support representative.
Causes: Safety issue or wrong working condition detected. Typically this error will never show up alone, it is consequence of another error condition.
Remedy: Run subsystem diagnostics to identify root cause.
Description: Drying PCA 0X relay error. Reinitialize carriage to recover the system. If this doesn’t work, run subsystem diagnostics, and if the problem is confirmed call your support representative.
Causes: a. There is a drying PCA power problem. b. One (or both) relays are in S.C. or GPIO is stuck in logical level 1. c. Some cable into the AC circuit is not connected. d. One (or both) is in O.C.
Remedy: 1. Run subsystem diagnostics to confirm the problem. 2. Replace the drying PCA. See Drying PCA. 3. Replace the fuse. 4. Reconnect properly.
Description: Drying PCA 01 relay check failed. Reinitialize carriage to recover the system. If this doesn’t work, run subsystem diagnostics, and if the problem is confirmed call your support representative.
Causes: Drying PCA relay failed
Remedy: Check with diagnostics and replace the PCA if necessary. See Drying PCA.
Description: Drying PCA 02 relay check failed. Reinitialize carriage to recover the system. If this doesn’t work, run subsystem diagnostics, and if the problem is confirmed call your support representative.
Causes: Drying PCA relay failed
Remedy: Check with diagnostics and replace the PCA if necessary. See Drying PCA.
Description: Drying PCA 01 fuse 1 burnt. Reinitialize carriage to recover the system. If this doesn’t work, run subsystem diagnostics, and if the problem is confirmed call your support representative.
Causes: Fuse burnt out.
Remedy: 1. Run subsystem diagnostics to confirm the problem. 2. Replace the fuse. 3. Replace the drying PCA.
Description: Drying PCA 02 fuse 1 burnt. Reinitialize carriage to recover the system. If this doesn’t work, run subsystem diagnostics, and if the problem is confirmed call your support representative.
Causes: Fuse burnt out.
Remedy: 1. Run subsystem diagnostics to confirm the problem. 2. Replace the fuse. 3. Replace the drying PCA. See Drying PCA.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.