Các lỗi thường gặp

Code :
  • Code: 08.08
  • Description: Application crash in the front panel side
  • Causes: Application crash in the front panel side.
  • Remedy: Call agent: 1. Press Enter and continue. Try the last operation again. 2. Switch the power off at the rear of the printer, wait briefly, then switch it back on again. 3. Update the firmware.
  • Code: 08.10
  • Description: Front Panel not connected or damaged. It appears when the there is a communication error with the device. It might be a hardware error or front panel unplugged
  • Causes: Front Panel not connected or damaged.
  • Remedy: Call agent: • Restart the printer. Service engineer: 1. Ensure the front panel is properly connected. 2. Ensure the front panel cable is properly fitted in the Formatter. 3. Replace the Formatter. See Formatter PCA. 4. Replace the front panel. See Front panel.
  • Code: 11.10
  • Description: Trailing Cable does not seem to be connected
  • Causes: Trailing cable not correctly connected or damaged.
  • Remedy: Call agent: • Restart the printer. Service engineer: 1. Check that the Trailing Cable is not damaged. 2. Check that the Trailing Cable is correctly connected to the Carriage PCA, Interconnect PCA, and Engine PCA. 3. Replace the Trailing Cable.
  • Code: 12.10:10
  • Description: Printmech: Hannibal4 24V failure. Check Inner lights array 2
  • Causes: The 24V cable from Printmech to Inner lights array 2 has a problem Printmech PCA is damaged.
  • Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Inner lights array 2. 2. Check the Printmech PCA.
  • Code: 12.11:10
  • Description: Printmech: 24V to Interconnect failure. Check TUR, Right aerosol fan and Primer valves
  • Causes: The 24V cable from Printmech to Interconnect PCA has a problem Printmech PCA is damaged.
  • Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Printmech to Interconnect cable. 2. Check TUR, Right aerosol fan and Primer valves. 3. Check the Printmech PCA.
  • Code: 12.12:10
  • Description: Printmech: 24V Misc failure. Check Air pumps and Primer valves switch
  • Causes: The 24V cable from Printmech to Air Pumps and Interconnect PCA has a problem Printmech PCA is damaged.
  • Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Printmech to Air Pumps cable ,and to the primer valves switch. 2. Check the Air Pumps. 3. Check Primer valves switch. 4. Check the Printmech PCA.
  • Code: 12.13:10
  • Description: Printmech: 24V to Printzone fans failure
  • Causes: The 24V cable from Printmech to Printzone fans has a problem Printmech PCA is damaged.
  • Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Printmech to Printzone fans cable. 2. Check the Printzone fans. 3. Check the Printmech PCA.
  • Code: 12.14:10
  • Description: Printmech: 24V to Vacuum fans failure
  • Causes: The 24V cable from Printmech to Vacuum fans has a problem Printmech PCA is damaged.
  • Remedy: Call agent: • Restart the printer. Service engineer: 1. Check the Printmech to Vacuum fans cable. 2. Check the Vacuum fans. 3. Check the Printmech PCA.