Description: K Drum Cartridge Dead Stop Error 91-913-00 K Drum Cartridge Dead Stop Error NOTE: Status code 09-521 is raised with these fault codes.
Remedy: Cycle system power. The error persists. Y↓N→Go to SCP 6 and complete the Final Actions. Check Drum Cartridge life count. The Drum Cartridge is at or near end of life. Y↓N→Reseat the Drum Cartridge and cycle system power. The error persists. Y↓N→Perform SCP 6 Final Actions lnstall new components as necessary: • Toner Cartridge • Xerographic Connector • MCU Board Replace the Drum Cartridge from customer stock.
Description: K Drum Cartridge Error 91-914-00 K Drum Cartridge Comm Error 91-915-00 K Drum Cartridge Data Error 91-921-00 K Drum Cartridge Missing. Status code 09-553. 91-936-00 K Drum Cartridge ID Error NOTE: Status codes 03-561 and 09-548 are raised with these fault codes.
Remedy: Check Xerographic Connector condition. The Xerographic Connector is good. Y↓N→Replace the Xerographic Connector. The error persists. Y↓N→Perform SCP 6 Final Actions lnstall new components as necessary: • Xerographic Connector • MCU Board Replace the Drum Cartridge from customer stock.
Description: ATCFail [K] 92-315-00 ATCFail [K] NOTE: Status codes 03-561 and 04-563 are raised with this fault code. Fault codes are not cleared by power Off/On if the number of of ATC Fail faults reched the threshold value.
Remedy: Check the Drum Cartridge life count. Drum Cartridge life remains. Y↓N→Replace the Drum Cartridge from customer stock. Check Xerographic Connector condition. The Xerographic Connector is good. Y↓N→Replace the Xerographic Connector. The error persists. Y↓N→Perform SCP 6 Final Actions lnstall new components as necessary: • Xerographic Connector • MCU Board Replace the Drum Cartridge from customer stock.
Description: Internal - Over Temp Failure 92-584-00 Internal temperature over temp Broken. Status codes 03-561 and 04-563 are raised with this fault code. 92-586-00 Internal - Over temp failure
Remedy: Use dC140 code 091-200 to check environmental sensor operation. The sensor is good. Y↓N→Replace the HVPS . Use dC330 code 042-001 to test the Rear Fan. The fan rotates. Y↓N→Replace the Rear Fan . Use dC330 code 042-003 to test the LVPS Fan The fan rotates. Y↓N→Replace the LVPS Fan . lnstall new components as necessary: • HVPS • LVPS • MCU Board
Description: K Image Calibration Error 1 92-650-00 K Image Calibration Error 1 NOTE: Status codes 03-561 and 09-548 are raised with this fault code. .
Remedy: Check the Drum Cartridge life count. Drum Cartridge life remains. Y↓N→Replace the Drum Cartridge from customer stock. Check Xerographic Connector condition. The Xerographic Connector is good. Y↓N→Replace the Xerographic Connector. The error persists. Y↓N→Perform SCP 6 Final Actions lnstall new components as necessary: • Xerographic Connector • MCU Board Replace the Drum Cartridge from customer stock.
Remedy: Use dC140 code 091-200 to check environmental sensor operation. The sensor is good. Y↓N→Replace the HVPS . lnstall new components as necessary: • MCU Board
Remedy: Use dC330 code 042-003 to test the LVPS Fan The fan rotates. Y↓N→Replace the LVPS Fan . Use dC140 code 091-200 to check environmental sensor operation. The sensor is good. Y↓N→Replace the HVPS . lnstall new components as necessary: • LVPS Fan . • LVPS • MCU Board
Description: K Drum Cartridge Dispense Fail 93-317-00 K Drum Cartridge Dispense Fail NOTE: Status codes 03-561 and 09-548 are raised with this fault code.
Remedy: Check Toner Cartridge life count. Toner Cartridge life remains. Y↓N→Replace the Toner Cartridge . Remove and gently shake the Toner Cartridge. Replace the cartridge, then cycle system power and retest. The error persists. Y↓N→Perform SCP 6 Final Actions Use dC330 code 093-001 to briefly test the Dispense Motor The motor rotates. Y↓N→Replace the Dispense Motor . Check Xerographic Connector condition. The Xerographic Connector is good. Y↓N→Replace the Xerographic Connector. The error persists. Y↓N→Perform SCP 6 Final Actions lnstall new components as necessary: • Toner Cartridge from customer stock • Drum Cartridge from customer stock • MCU Board Replace the Toner Cartridge from customer stock.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.