Description: K Drum Cartridge Dead Stop Error 91-913-00 K Drum Cartridge Dead Stop Error NOTE: Status code 09-521 is raised with these fault codes.
Remedy: Cycle system power. The error persists. Y↓N→Go to SCP 6 and complete the Final Actions. Check Drum Cartridge life count. The Drum Cartridge is at or near end of life. Y↓N→Reseat the Drum Cartridge and cycle system power. The error persists. Y↓N→Perform SCP 6 Final Actions lnstall new components as necessary: • Toner Cartridge • Xerographic Connector • MCU Board Replace the Drum Cartridge from customer stock.
Code: 91-914-00 ... 91-936-00
Description: K Drum Cartridge Error 91-914-00 K Drum Cartridge Comm Error 91-915-00 K Drum Cartridge Data Error 91-921-00 K Drum Cartridge Missing. Status code 09-553. 91-936-00 K Drum Cartridge ID Error NOTE: Status codes 03-561 and 09-548 are raised with these fault codes.
Remedy: Check Xerographic Connector condition. The Xerographic Connector is good. Y↓N→Replace the Xerographic Connector. The error persists. Y↓N→Perform SCP 6 Final Actions lnstall new components as necessary: • Xerographic Connector • MCU Board Replace the Drum Cartridge from customer stock.
Code: 92-315-00
Description: ATCFail [K] 92-315-00 ATCFail [K] NOTE: Status codes 03-561 and 04-563 are raised with this fault code. Fault codes are not cleared by power Off/On if the number of of ATC Fail faults reched the threshold value.
Remedy: Check the Drum Cartridge life count. Drum Cartridge life remains. Y↓N→Replace the Drum Cartridge from customer stock. Check Xerographic Connector condition. The Xerographic Connector is good. Y↓N→Replace the Xerographic Connector. The error persists. Y↓N→Perform SCP 6 Final Actions lnstall new components as necessary: • Xerographic Connector • MCU Board Replace the Drum Cartridge from customer stock.
Code: 92-584-00, 92-586-00
Description: Internal - Over Temp Failure 92-584-00 Internal temperature over temp Broken. Status codes 03-561 and 04-563 are raised with this fault code. 92-586-00 Internal - Over temp failure
Remedy: Use dC140 code 091-200 to check environmental sensor operation. The sensor is good. Y↓N→Replace the HVPS . Use dC330 code 042-001 to test the Rear Fan. The fan rotates. Y↓N→Replace the Rear Fan . Use dC330 code 042-003 to test the LVPS Fan The fan rotates. Y↓N→Replace the LVPS Fan . lnstall new components as necessary: • HVPS • LVPS • MCU Board
Code: 92-650-00
Description: K Image Calibration Error 1 92-650-00 K Image Calibration Error 1 NOTE: Status codes 03-561 and 09-548 are raised with this fault code. .
Remedy: Check the Drum Cartridge life count. Drum Cartridge life remains. Y↓N→Replace the Drum Cartridge from customer stock. Check Xerographic Connector condition. The Xerographic Connector is good. Y↓N→Replace the Xerographic Connector. The error persists. Y↓N→Perform SCP 6 Final Actions lnstall new components as necessary: • Xerographic Connector • MCU Board Replace the Drum Cartridge from customer stock.
Code: 92-661-00
Description: Environment Temperature Sensor Fail
Remedy: Use dC140 code 091-200 to check environmental sensor operation. The sensor is good. Y↓N→Replace the HVPS . lnstall new components as necessary: • MCU Board
Code: 92-805-00
Description: 24V Fan Off Detect
Remedy: Use dC330 code 042-003 to test the LVPS Fan The fan rotates. Y↓N→Replace the LVPS Fan . Use dC140 code 091-200 to check environmental sensor operation. The sensor is good. Y↓N→Replace the HVPS . lnstall new components as necessary: • LVPS Fan . • LVPS • MCU Board
Code: 93-317-00
Description: K Drum Cartridge Dispense Fail 93-317-00 K Drum Cartridge Dispense Fail NOTE: Status codes 03-561 and 09-548 are raised with this fault code.
Remedy: Check Toner Cartridge life count. Toner Cartridge life remains. Y↓N→Replace the Toner Cartridge . Remove and gently shake the Toner Cartridge. Replace the cartridge, then cycle system power and retest. The error persists. Y↓N→Perform SCP 6 Final Actions Use dC330 code 093-001 to briefly test the Dispense Motor The motor rotates. Y↓N→Replace the Dispense Motor . Check Xerographic Connector condition. The Xerographic Connector is good. Y↓N→Replace the Xerographic Connector. The error persists. Y↓N→Perform SCP 6 Final Actions lnstall new components as necessary: • Toner Cartridge from customer stock • Drum Cartridge from customer stock • MCU Board Replace the Toner Cartridge from customer stock.